Error
code
Description
Action
215-xxx-000
Failed
CD
or
DVD
test.
1.
Run
the
test
again
with
a
different
CD
or
DVD.
2.
Reseat
the
following
components:
a.
CD
or
DVD
drive
b.
Front
panel
assembly
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
CD
or
DVD
drive
b.
(Trained
service
technician
only)
Front
panel
assembly
217-xxx-000
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
1.
217-xxx-001
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
2.
217-xxx-002
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
3.
217-xxx-003
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
4.
217-xxx-004
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
5.
217-xxx-005
Failed
BIOS
fixed
disk
test.
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
Reseat
and,
if
necessary,
replace
hard
disk
drive
6.
217-198-xxx
Could
not
establish
drive
parameters.
1.
Check
the
drive
cables
and
terminators.
2.
Reseat
and,
if
necessary,
replace
the
hard
disk
drive.
301-xxx-000
Failed
keyboard
test.
Note:
After
installing
a
USB
keyboard,
you
might
have
to
use
the
Configuration/Setup
Utility
program
to
enable
keyboardless
operation
and
prevent
the
POST
error
message
301
from
being
displayed
during
startup.
1.
Reseat
the
following
components:
a.
Keyboard
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
302-xxx-xxx
Failed
mouse
test.
1.
Reseat
the
following
components:
a.
Mouse
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Chapter
2.
Diagnostics
87
Содержание xSeries 366
Страница 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 160: ...144 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 181: ...V video connector 6 VRM LED 64 W Web site 1 weight 3 World Wide Web 1 Index 165...
Страница 182: ...166 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Страница 183: ......
Страница 184: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...