Chapter 6. Symptom-to-FRU index
This index supports xSeries 235 servers.
Notes:
1. Check the configuration before you replace a FRU. Configuration problems can
cause false errors and symptoms.
2. For IBM devices not supported by this index, refer to the manual for that device.
3. Always start with “General checkout” on page 25.
The symptom-to-FRU index lists symptoms, errors, and the possible causes. The
most likely cause is listed first. Use this symptom-to-FRU index to help you decide
which FRUs to have available when servicing the computer.
The left-hand column of the tables in this index lists error codes or messages, and
the right-hand column lists one or more suggested actions or FRUs to replace.
Note:
Some tables have more than two columns; in those instances, more than
one column on the left is required to describe the error symptom.
Take the action (or replace the FRU) suggested first in the list of the right-hand
column, then try the server again to see if the problem has been corrected before
taking further action.
Note:
Try reseating a suspected component or reconnecting a cable before
replacing the component.
The POST BIOS code displays POST error codes and messages on the screen.
Beep symptoms
Beep symptoms are short tones or a series of short tones separated by pauses
(intervals without sound). See the examples in the following table.
Beeps
Description
1-2-3
v
One beep
v
A pause (or break)
v
Two beeps
v
A pause (or break)
v
Three beeps
4
Four continuous beeps
One beep after successfully completing POST indicates the system is functioning
properly.
Note:
See “System” on page 156 to determine which components should be replaced by a field service technician.
Beep/symptom
FRU/action
1-1-2
(Microprocessor register test
failed)
1.
Optional microprocessor (if installed)
2. Microprocessor
3. System board
© Copyright IBM Corp. 2002
125
Содержание xSeries 235
Страница 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 2: ......
Страница 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Страница 34: ...24 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 50: ...40 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 134: ...124 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 164: ...154 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 183: ...Appendix B Related service information 173...
Страница 184: ...174 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 185: ...Appendix B Related service information 175...
Страница 186: ...176 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 187: ...Appendix B Related service information 177...
Страница 188: ...178 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 189: ...Appendix B Related service information 179...
Страница 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 200: ...190 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 201: ...Appendix B Related service information 191...
Страница 202: ...192 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 211: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix C Notices 201...
Страница 212: ...202 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 213: ......
Страница 214: ...Part Number 59P6524 1P P N 59P6524...