When Post Error Reporting is enabled, deferred-check conditions are reported to the host and temporary errors are reported in the sense data. Function code is
displayed in Maintenance mode when the drive has Post Error Reporting enabled.
This selection is normally used as a request from support personnel.
1. Place the drive in Maintenance mode. For instructions, see
.
2. Press Unload once per second until either or displays in the SCD. or displays in the SCD to indicate the current setting for Post Error Reporting. If you
cycle past the desired code, press Unload once per second until the code reappears.
3. Exit Maintenance mode if you do not want to change the current setting for Post Error Reporting. For instructions, see
4. To disable Post Error Reporting, press and hold Unload for 3 seconds while displays in the SCD. The SCD changes to after you release Unload.
5. Press Unload once per second to select another Maintenance mode function. To exit Maintenance mode, refer to
Function code U: Post Error Reporting disabled
When Post Error Reporting is disabled, deferred-check conditions are not reported to the host and temporary errors are not reported in the sense data. This setting is
normal (default) for the drive. When Post Error Reporting is disabled, Function code is displayed in Maintenance mode. The drive defaults to Post Error Reporting
disabled after a reboot or power off/on cycle.
1. Place the drive in Maintenance mode. For instructions, see
.
2. Press Unload once per second until either or displays in the SCD. or displays in the SCD to indicate the current setting for Post Error Reporting. If you
cycle past the wanted code, press Unload once per second until the code reappears.
3. Exit Maintenance mode if you do not want to change the current setting for Post Error Reporting. For instructions, see
4. To disable Post Error Reporting, press and hold Unload for 3 seconds while displays in the SCD. The SCD changes to after you release Unload.
5. Press Unload once per second to select another Maintenance mode function. To exit Maintenance mode, refer to
Troubleshooting
Use the information in this section to troubleshoot any issues with your library setup and configuration.
How the drive reports problems
Drive tests helps in determining any problems with the drive.
If you have questions or problems, go through this checklist before IBM technical support is contacted.
Contacting IBM technical support
Follow the procedures to contact IBM technical support.
Diagnostic information
How the drive reports problems
Drive errors can be found using one or more of the following ways:
Front panel SCD indicator
Error code log
Host messages may include sense data (link) from the drive. Utilize this information along with the SCSI Reference (link) to determine the error.
(can be downloaded using ITDT-GE)
Running drive tests
Drive tests helps in determining any problems with the drive.
A drive can be tested using one or more of the following methods:
Maintenance Functions
: Runs tests to determine whether the drive can properly load and unload cartridges, and read and write data.
: Completes tests to ensure that the drive can read from and write to tape.
: Completes tests to ensure that the drive can read from and write to tape.
ITDT
: Check whether the tape device is defective and output a pass/fail result.
100
IBM TS22xx - TS2290, TS2280, and TS2270