321
Appendix A: Event code tables
Event code: 583
Message:
Loss of signal or loss of synchronization.
Severity:
Major.
Explanation:
An attached OSI or FICON server recognized a loss-of-signal condition or a loss-of-synchronization condition
that persisted for more than the specified receiver-transmitter timeout value (R_T_TOV).
Action:
A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI)
or the FICON architecture document (FICON). If fault isolation at the server does not detect a failure, the problem
may be due to a port failure. See
MAP 0000: Start MAP
for instructions.
Event Data:
Refer to the T11/99-017v0 or FICON architecture document for the specific link incident record format.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Event code: 584
Message:
Not operational primitive sequence received.
Severity:
Major.
Explanation:
An attached OSI or FICON server received a not-operational primitive sequence (NOS).
Action:
A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI)
or the FICON architecture document (FICON). If fault isolation at the server does not detect a failure, the problem
may be due to a port failure. See
MAP 0000: Start MAP
for instructions.
Event Data:
Refer to the T11/99-017v0 or FICON architecture document for the specific link incident record format.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Содержание TotalStorage SAN140M
Страница 2: ......
Страница 13: ...xi Figures 83 Miscellaneous parts 258 84 Power cords and receptacles 259 85 24 Port Ethernet hub 340...
Страница 14: ...SAN140M Installation and Service Manual xii...
Страница 16: ...SAN140M Installation and Service Manual xiv...
Страница 54: ...SAN140M Installation and Service Manual 22...
Страница 186: ...SAN140M Installation and Service Manual 154...
Страница 240: ...SAN140M Installation and Service Manual 208...
Страница 282: ...SAN140M Installation and Service Manual 250...
Страница 294: ...SAN140M Installation and Service Manual 262...
Страница 366: ...SAN140M Installation and Service Manual 334...
Страница 370: ...SAN140M Installation and Service Manual 338...
Страница 377: ...345 Appendix D Restore management server h Click Login The application opens and the EFCM main window appears...
Страница 378: ...SAN140M Installation and Service Manual 346...
Страница 424: ...SAN140M Installation and Service Manual 392...
Страница 427: ......
Страница 428: ...Printed in USA GC26 7664 04...