This
method
requires
that
you
back
up
the
data
on
the
affected
drives
and
then
turn
off
the
storage
subsystem.
After
replacing
all
the
drives,
you
must
reconfigure
the
new
drives
and
restore
data
from
backup.
See
the
procedure
in
“Replacing
all
drives
at
the
same
time.”
This
is
the
safest
way
to
exchange
drives
without
losing
data.
However,
this
method
might
take
a
long
time
to
complete
because
of
the
backup,
reconfiguration,
and
restoration
processes.
In
addition,
other
users
are
not
able
to
use
the
storage
subsystem
(or
any
storage
expansion
enclosures
attached
to
the
storage
subsystem)
until
you
finish
the
procedure.
You
must
use
this
method
on
RAID
0
logical
drives.
v
Replacing
the
drives
one
at
a
time
In
this
method,
you
manually
fail
each
drive,
replace
it,
and
wait
for
the
system
to
restore
data
to
the
new
drive
before
installing
the
next
drive.
After
you
install
the
new
drives,
you
can
configure
them
to
make
the
additional
drive
space
available.
See
the
procedure
in
“Replacing
the
drives
one
at
a
time”
on
page
127.
Using
this
method,
you
can
replace
the
drives
while
the
storage
subsystem
is
running,
eliminating
the
down
time
that
is
required
if
you
replace
all
the
drives
at
once.
However,
this
method
is
more
risky
because
you
can
lose
data
if
the
drive
restoration
or
storage
subsystem
reconfiguration
process
fails.
In
addition,
the
reconstruction
process
might
take
a
long
time.
This
method
works
only
on
redundant
logical
drives
(RAID
1,
3,
or
5).
You
cannot
use
this
method
with
any
drives
containing
RAID
0
logical
drives.
Consider
backing
up
your
data
if
you
use
this
method.
This
safeguards
your
data
if
the
restoration
and
reconfiguration
process
fails
or
the
new
drive
malfunctions.
The
method
you
use
depends
on
the
following
considerations:
v
Which
method
most
closely
matches
the
recommended
drive
upgrade
procedure
that
is
provided
in
the
operating
system
or
the
storage-management
software
documentation.
v
Which
RAID
level
is
used
on
the
affected
drives.
(RAID
0
requires
you
to
replace
all
the
drives
at
the
same
time.)
v
How
much
downtime
is
acceptable
as
you
swap
the
drives.
v
The
number
of
drives
in
an
array.
Replacing
drives
one
at
a
time
is
better
suited
for
arrays
consisting
of
3
to
5
fibre
channel
drives.
If
you
have
more
than
10
drives
or
SATA
drives
with
a
large
capacity
of
400G
or
500G,
consider
replacing
all
drives
at
the
same
time,
as
described
in
the
next
section.
Replacing
all
drives
at
the
same
time
Use
this
procedure
to
replace
all
drives
at
the
same
time.
You
must
use
this
method
if
you
are
upgrading
drives
containing
RAID
0
logical
drives.
All
the
data
currently
on
the
drives
is
lost
when
you
replace
the
drives;
therefore,
you
must
back
up
all
data
that
is
currently
on
the
drives.
This
procedure
also
requires
you
to
turn
off
the
storage
subsystem,
which
makes
the
storage
subsystem
(and
any
attached
storage
expansion
enclosures)
inaccessible
to
other
users.
To
replace
all
the
drives
at
the
same
time,
perform
the
following
steps:
1.
Read
the
following
information:
v
The
information
in
“Adding
larger-capacity
drives”
on
page
124,
particularly
the
paragraphs
that
discuss
the
differences
between
the
two
possible
upgrade
procedures
v
The
information
in
your
software
documentation
regarding
drive
upgrades
and
installation
Chapter
5.
Installing
and
replacing
components
125
Содержание TotalStorage DS4300 Turbo
Страница 2: ......
Страница 8: ...vi IBM TotalStorage DS4300 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide...
Страница 16: ...xiv IBM TotalStorage DS4300 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide...
Страница 18: ...xvi IBM TotalStorage DS4300 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide...
Страница 28: ...xxvi IBM TotalStorage DS4300 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide...
Страница 132: ...104 IBM TotalStorage DS4300 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide...
Страница 184: ...156 IBM TotalStorage DS4300 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide...
Страница 192: ...164 IBM TotalStorage DS4300 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide...
Страница 216: ...188 IBM TotalStorage DS4300 Fibre Channel Storage Subsystem Installation User s and Maintenance Guide...
Страница 219: ......
Страница 220: ...Part Number 42D3300 Printed in USA GC26 7722 02 1P P N 42D3300...