Perform
the
following
steps
to
receive
Library
Manager
SNMP
traps:
1.
Ensure
that
the
SNMP
trap
was
generated
from
a
3494
Tape
Library.
2.
If
the
message
was
generated
from
a
Library
Manager,
tokenize
the
incoming
SNMP
trap
and
determine
which
3494
Tape
Library
generated
the
trap
message.
This
can
be
done
by
reading
the
Library
Sequence
Number.
3.
Determine
the
Library
Manager
SNMP
Trap
Type
that
was
sent.
This
is
one
of
the
Library
Manager
SNMP
Trap
Types.
This
is
the
next
field
in
the
space-delimited
string.
4.
When
you
have
determined
that
the
SNMP
trap
message
was
generated
from
a
3494
Tape
Library,
its
identity,
and
the
type
of
Library
Manager
SNMP
trap
message
that
was
sent,
the
message
can
be
tokenized
again
to
remove
the
message
parameters
and
message
string.
Note:
It
is
a
good
idea
to
program
the
monitor
station
to
handle
conditions
such
as
an
unrecognized
Library
Manager
SNMP
trap.
Additional
Library
Manager
SNMP
traps
may
be
added
and
documentation
updated,
as
they
are
updated.
Programming
Tools
The
Library
Manager
code
contains
an
aid
for
the
developer
to
help
check
the
monitor’s
ability
to
handle
all
the
Library
Manager
SNMP
traps.
This
program
is
located
in
C:\lm\exe
.
To
use
the
program,
first
ensure
that
SNMP
is
enabled
and
configured
on
the
Library
Manager.
The
program
cannot
generate
any
SNMP
traps
if
SNMP
is
not
enabled
on
the
Library
Manager.
To
start
the
program,
open
a
service
window
and
enter
SNMPTEST
.
If
the
program
does
not
come
to
the
foreground,
press
the
Ctrl
+
Esc
keys
to
bring
up
the
Window
List.
Select
the
SNMPTEST
program.
Use
the
program
to
generate
the
required
SNMP
traps,
and
when
done,
exit
the
SNMPTEST
program
and
close
the
service
window.
OPINT
Library
Manager
SNMP
Traps
This
section
discusses
the
format
of
the
Library
Manager
OPINT
SNMP
traps.
Library
Manager
OPINT
SNMP
traps
are
the
easiest
to
program
for,
because
they
all
follow
the
same
format.
The
general
Library
Manager
OPINT
SNMP
trap
has
the
following
format:
3494
{Library
Sequence
Number}
OPINT
{OPINT
Trap
Number}
{Parameter
A}
{Parameter
B}
{Parameter
C}
{Actual
Library
Manager
OPINT
Trap
Message}
The
following
is
an
example
of
an
OPINT
Library
Manager
SNMP
Trap:
3494
C2444
OPINT
48
180
-
-
A
cartridge
containing
invalid
media
has
been
left
in
the
device
180
feed
slot.
Remove
the
cartridge.
In
this
example,
a
cartridge
with
invalid
media
type
has
been
left
in
the
feed
slot
of
device
180
on
library
C2444.
Note:
Chapter
6.
Advanced
Operating
Procedures
363
Содержание TotalStorage 3494 Tape Library
Страница 1: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Страница 2: ......
Страница 3: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Страница 14: ...xii 3494 Tape Library Operator Guide...
Страница 22: ...xx 3494 Tape Library Operator Guide...
Страница 72: ...46 3494 Tape Library Operator Guide...
Страница 84: ...58 3494 Tape Library Operator Guide...
Страница 124: ...98 3494 Tape Library Operator Guide...
Страница 136: ...110 3494 Tape Library Operator Guide...
Страница 150: ...124 3494 Tape Library Operator Guide...
Страница 352: ...Figure 206 Service Window 326 3494 Tape Library Operator Guide...
Страница 536: ...510 3494 Tape Library Operator Guide...
Страница 572: ...546 3494 Tape Library Operator Guide...
Страница 580: ...554 3494 Tape Library Operator Guide...
Страница 600: ...574 3494 Tape Library Operator Guide...
Страница 603: ......
Страница 604: ...Part Number 95P6750 EC H79941 GA32 0449 14 1P P N 95P6750...
Страница 605: ...Spine information IBM TotalStorage 3494 Tape Library 3494 Tape Library Operator Guide...