Table 44. Power consumption of TS3500 Tape Library frame models, power consuming
features, and drive canisters (continued)
FC 1950 PDU
5
17
17
FC 4872
TS7700 backend 4 Gb
switches (2x)
0
113
113
FC 4875
TS7700 backend 8 Gb
switches (2x)
0
86
86
Tape Drives
6
TS1120 (3592 Models
E05 and J1A)
0
27
42
TS1130 (3592 Model
E06)
0
17
46
TS1140 (3592 Model
E07)
0
23
50
TS1030 (LTO 3588
F3B)
0
20
34
TS1040 (LTO 3588
F4A)
0
18
36
TS1050 (LTO 3588
F5A)
0
12
28
TS1060 (LTO 3588
F6A)
0
9
32
Notes:
1.
These models come equipped with dual ac line cords. The figures in this table show the
total power consumed, including power consumed by redundant power supplies. Each
individual line cord supplies approximately half of the power.
2.
Frames with no frame control assembly (FCA) or enhanced FCA consume no power
and require no cooling.
3.
S-frame power is for internal lighting and is provided by the power supplies in frames
that are equipped with power.
4.
The HA1 frame is not connected to ac power. The power shown is the total consumed
by the second accessor and is provided by the power supplies in frames that are
equipped with power.
5.
Drive mounting kit power includes ac/dc conversion losses in drive power supplies
(including redundant power), but does not include power consumed by the drive
canister.
6.
Drive power includes the drive and canister cooling fan, but does not include power
losses in external ac or dc drive power supplies. Idle power is consumed when the
drive has no tape cartridge loaded. Maximum continuous power is consumed when the
drive is actively writing to a tape cartridge.
7.
"Off" refers to power consumed when the library is connected to an ac power source
and the library on/off switch is set to off.
8.
Model SC1 power is provided by the library frames to which it connects. The idle
power is the power consumed by each shuttle station when no shuttle car is present.
The maximum continuous power is the power consumed by the shuttle station when
the shuttle car is present.
In order to calculate the total power consumption (in watts) of a particular library
configuration, multiply the quantity of each power consuming item in the
configuration by the corresponding value in Table 44 on page 120 and calculate the
Chapter 2. Physical planning specifications
121
|
|
|||
Содержание System Storage TS3500
Страница 1: ...IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide GA32 0593 07...
Страница 6: ...vi IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 8: ...viii IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 14: ...xiv IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 18: ...xviii IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 24: ...xxiv IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 114: ...90 IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 156: ...132 IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 196: ...172 IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 234: ...210 IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 238: ...214 IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 246: ...222 IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 254: ...230 IBM System Storage TS3500 Tape Library with ALMS Introduction and Planning Guide...
Страница 289: ......
Страница 290: ...Printed in USA GA32 0593 07...