Table 7. NSBxxxx error codes and text messages (continued)
Error code
Error message
What you should do
NSB61669
Token Ring error in
request parameters phase.
Indicates stage of Token-ring adapter
insertion. Watch for any messages that
accompany this message.
NSB61679
Source address received is
not equal to a neighbor
source address.
Full duplex error. Contact the system
administrator regarding network problems,
or, switch to half duplex. If this does not
resolve the problem, replace the thin client
logic unit (see “Replacing the logic unit”
NSB61689
Claim token received.
Full duplex error. Contact the system
administrator regarding network problems,
or, switch to half duplex. If this does not
resolve the problem, replace the thin client
logic unit (see “Replacing the logic unit”
NSB61699
Ring purged token
received .
Full duplex error. Contact the system
administrator regarding network problems,
or, switch to half duplex. If this does not
resolve the problem, replace the thin client
logic unit (see “Replacing the logic unit”
NSB61709
Standby monitory frame
received.
Full duplex error. Contact the system
administrator regarding network problems,
or, switch to half duplex. If this does not
resolve the problem, replace the thin client
logic unit (see “Replacing the logic unit”
NSB61719
Full duplex insert denied.
Full duplex error. Contact the system
administrator regarding network problems,
or, switch to half duplex. If this does not
resolve the problem, replace the thin client
logic unit (see “Replacing the logic unit”
NSB61729
Full duplex heartbeat
received too early.
Full duplex error. Contact the system
administrator regarding network problems,
or, switch to half duplex. If this does not
resolve the problem, replace the thin client
logic unit (see “Replacing the logic unit”
NSB61739
Beacon received before
open completed.
Full duplex error. Contact the system
administrator regarding network problems,
or, switch to half duplex. If this does not
resolve the problem, replace the thin client
logic unit (see “Replacing the logic unit”
NSB61740
Insertion timer expired.
Full duplex error. Contact the system
administrator regarding network problems,
or, switch to half duplex. If this does not
resolve the problem, replace the thin client
logic unit (see “Replacing the logic unit”
20
Содержание NetVista N2200
Страница 2: ......
Страница 6: ...iv...
Страница 14: ...4...
Страница 18: ...8...
Страница 44: ...34...
Страница 48: ...38...
Страница 50: ...40...
Страница 58: ...W Web information available on the World Wide vii World Wide Web information available on the vii 48...
Страница 61: ......
Страница 62: ...SA23 2804 00...