Installing options
45
5
Diagnostics panel (See Table 6)
6
Advanced System Management Processor error (CR70)
7
Power-on
(CR56)
8
DIMM1
failure
(CR21)
9
DIMM2
failure
(CR28)
10
DIMM3
ailure
(CR18)
11
DIMM4
failure
(CR20)
Before you begin
Before you begin to install options in your server, read the following information:
•
Become familiar with the safety and handling guidelines specified under
“Working inside a server with power on” on page 46, “Handling static-sensitive
devices” on page 46, and read “Safety information” on page 141. These guidelines
will help you work safely while working with your server or options.
•
You do not need to turn off the server to install or replace hot-swap power
supplies, hot-swap drives, hot-swap fans, or hot-plug PCI adapters.
•
The orange color on components and labels in your server indentifies hot-swap or
hot-plug components. This means that you can install or remove the component
while the system is running, provided that your system is configured to support
this function. For complete details about installing or removing a hot-swap or hot-
plug component, see the information provided in this chapter.
•
The blue color on components and labels indentifies touch points where a
component can be gripped, a latch moved, and so on.
Table 9. Diagnostics panel LEDs.
CR
LED
Description
29
PS1
Power supply 1 failure.
30
PS2
Power supply 2 failure.
31
PS3
Not used.
32
NON
Non-redundant power.
33
OVER
Overspecification. The system has exceeded the power capibilities of the installed
power supply units.
34
NMI
Non-maskable-interrupt occurred.
22
TEMP
System temperature exceeded maximum rating.
23
FAN
A fan failed or is operating slowly.
24
MEM
Memory failure. One or more dual in-line memory modules (DIMMS) failed.
25
CPU
Microprocessor failure. One or both microprocessors failed.
26
PCI 1
Error on primary PCI channel (A) or system board.
27
PCI 2
Error on secondary PCI channel (B) or system board.
58
VRM
Error on voltage regulator module or on integrated voltage regulator.
53
DASD1
SCSI bus A failure. The SCSI backplane (if any) or a device connected to SCSI bus
A failed.
57
DASD2
SCSI bus B failure. The SCSI hot-swap disk drive backplane on SCSI bus B failed.
Содержание Netfinity 4500R
Страница 1: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 2: ......
Страница 3: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 118: ...110 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 147: ...Parts listing Type 8656 139...
Страница 148: ...140 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 161: ...Related service information 153...
Страница 162: ...154 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 163: ...Related service information 155...
Страница 164: ...156 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 165: ...Related service information 157...
Страница 166: ...158 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 167: ...Related service information 159...
Страница 168: ...160 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 181: ...Related service information 173...
Страница 182: ...174 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 183: ...Related service information 175...
Страница 191: ......