Hardware Maintenance Manual: Netfinity 4500R Type 8656
Message
Action
Power supply "X" current share
fault
(level-
critical; excessive current demand
on power supply "X")
1.
See “Power checkout” on page 26.
Power supply "X" DC good fault
(level-critical; power good signal
not detected for power supply "X")
1.
Replace power supply "X"
Power supply "X" temperature
fault
1.
Replace fan "X"
Power supply "X" removed
1.
No action required - information only
Power supply "X" fan fault
(level-critical; fan fault in power
supply "X")
1.
Replace power supply "X"
Power supply "X" 12V fault
(level-critical; overcurrent
condition detected)
1.
See “Power checkout” on page 26.
Power supply "X" 3.3V fault
(level-critical; 3.3V power supply
"X" had an error)
1.
See “Power checkout” on page 26.
Power supply "X" 5V fault
(level-critical; 5V power supply "X"
had an error)
1.
See “Power checkout” on page 26.
System over recommended "X"
current
(level-
non-critical; system running too
much current on that voltage)
1.
See “Power checkout” on page 26.
System running non-redundant
power
(level-non-critical; system does not
have redundant power)
1.
Add another power supply
2.
Remove options from system
3.
System can continue to operate without
redundancy protection if
1
and
2
above are not
followed.
System under recommended
voltage for "X" v
(level-warning; indicated voltage
supply under nominal value; value
for "X" can be +12, -12, or +5)
1.
Check connections to power subsystem
2.
Replace power supply
3.
Replace power backplane
System under recommended
voltage on 3.3 v
(level-warning; 3.3 volt supply
under nominal value)
1.
Check connections to power subsystem
2.
Replace power supply
3.
Replace power backplane
System under recommended X
current
(level-non-
critical; system drawing less
current than recommended on
voltage "X")
1.
See “Power checkout” on page 26.
"X" V bus fault
(level-
critical; overcurrent condition on
"X" voltage bus)
1.
Check for short circuit on "X" voltage bus
2.
See“Power checkout” on page 26.
Содержание Netfinity 4500R
Страница 1: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 2: ......
Страница 3: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 118: ...110 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 147: ...Parts listing Type 8656 139...
Страница 148: ...140 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 161: ...Related service information 153...
Страница 162: ...154 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 163: ...Related service information 155...
Страница 164: ...156 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 165: ...Related service information 157...
Страница 166: ...158 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 167: ...Related service information 159...
Страница 168: ...160 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 181: ...Related service information 173...
Страница 182: ...174 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Страница 183: ...Related service information 175...
Страница 191: ......