 118

Hardware Maintenance Manual: Netfinity 4500R Type 8656

 

 

089-XXX-002        

                            

(Failed Optional Microprocessor 
test)

1.

VRM 2

 for Optional Microprocessor 2

2.

Optional Microprocessor  2

165-XXX-000

              (Failed 

Service Processor test)

1.

System Board.  

Before replacing the System Board, 

ensure that System Board jumper J45 is not installed 
(the default) when the error occurs.

2.

Power Backplane

3.

Hot-Swap Drive Backplane

180-XXX-000  

    (Diagnostics LED 

failure)

1.

Run Diagnostic LED test for the failing LED.

180-XXX-001

              (Failed 

information LED panel test)

1.

Information LED Panel

2.

Power Switch

3.

Assembly

180-XXX-002

              (Failed 

Diagnostics LED Panel test)

1.

Diagnostics LED Panel

2.

Power Switch

3.

Assembly

180-XXX-003

              (Failed 

System Board LED test)

1.

System Board

180-XXX-004     

              (Failed 

System Board LED test)

1.

System Board

180-XXX-005    

              (Failed 

SCSI Backplane LED test)

1.

SCSI Backplane

2.

SCSI Backplane Cable

3.

System Board

180-XXX-006

          (Memory Board 

LED test)

1.

Memory Board

2.

System Board

201-XXX-0NN           

      (Failed 

Memory test, see "Memory 
Settings" on page 33)

1.

DIMM Location slots 1-4 where  NN = DIMM 
location.

Note:

NN=1=DIMM 2
=2=DIMM 1
=3=DIMM 4
=4=DIMM 3

2.

System Board

201-XXX-999

         (Multiple DIMM 

failure, see error text)

1.

See error text for failing DIMMs

2.

System Board

202-XXX-001      

             (Failed 

System Cache test)

1.

VRM 1 

2.

Microprocessor 1

202-XXX-002

              (Failed 

System Cache test)

1.

VRM 2

2.

Microprocessor  2

206-XXX-000

              (Failed 

Diskette Drive test)

1.

Cable

2.

Diskette Drive

3.

System Board

Error Code/Symptom

FRU/Action

Содержание Netfinity 4500R

Страница 1: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...

Страница 2: ......

Страница 3: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...

Страница 4: ...s Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication IBM may make improvements and or changes in the product s and or the pro...

Страница 5: ...rtant This manual is intended for trained servicers who are familiar with IBM PC Server products Important safety information Be sure to read all caution and danger statements in this book before perf...

Страница 6: ...tti gli avvisi di attenzione e di pericolo prima di effettuare qualsiasi operazione Lea atentamente todas las declaraciones de precauci n y peligro ante de llevar a cabo cualquier operaci n Online sup...

Страница 7: ...board options connectors 40 System board internal cable connectors 41 System board external port connectors 41 System board switches and jumpers 42 System board LED locations 44 Before you begin 45 S...

Страница 8: ...ition Access 97 System Profile 97 Update Connector Manager 97 Web Manager Configuration 98 Delaying Netfinity Manager startup on OS 2 systems 98 Getting more information about Netfinity Manager 98 Ins...

Страница 9: ...e part of a cluster if The customer identifies the system as part of a cluster One or more external storage units are attached to the system and at least one of the attached storage units is additiona...

Страница 10: ...LED on page 114 Check the System Error Log If an error was recorded by the system see Symptom to FRU index on page 111 Start the Diagnostic Programs See Starting the diagnostic programs on page 14 Che...

Страница 11: ...limited warranty and IBM Server StartUp Support If you have access to the World Wide Web you can obtain up to date information about your server model and other IBM server products at the following Wo...

Страница 12: ...Sound power idling 5 9 bel maximum Sound power operating 6 1 bel maximum Sound pressure operating 47 5 dBa maximum Environment Air temperature Server on 10 to 35 C 50 to 95 F Altitude 0 to 914 m 2998...

Страница 13: ...ly in your server to provide redundant power for your server The Power Non Redundant light emitting diode LED in the group of diagnostic LEDs on the system board is lit when the power load is 270 watt...

Страница 14: ...design are reliability availability and serviceability RAS These factors help to ensure the integrity of the data stored on your server that your server is available when you want to use it and that...

Страница 15: ...Hard disk Activity light 4 System power light 5 Power control botton 6 Reset button System Power Light When this green light is on system power is present in the server When this light flashes the ser...

Страница 16: ...on the server at the set time If AC power is present the server is off and ring signal detect is enabled in the Configuration Setup utility program you can turn on the server by telephone input The Ne...

Страница 17: ...ap drive bays has a Hard Disk Status light When this amber light is on continuously the drive has failed When the light flashes slowly one flash per second the drive is being rebuilt When the light fl...

Страница 18: ...is on when the information log contains information about certain conditions in your server that might affect performance For example the light will be on if your server does not have redundant power...

Страница 19: ...at are built into your server By following the path of lights you can quickly identify the type of system error that occurred See Light path diagnostics for more information Identifying problems using...

Страница 20: ...performs a series of tests to check the operation of server components and some of the options installed in the server This series of tests is called the power on self test or POST If POST finishes wi...

Страница 21: ...nning the SCSISelect Utility See SCSI error codes on page 128 Diagnostic programs and error messages The server diagnostic programs are stored in upgradable read only memory ROM on the system board Th...

Страница 22: ...result occurs when you specify a diagnostic test for a device that is not present Aborted This result occurs when the test could not proceed because of the system configuration Warning This result occ...

Страница 23: ...ists during normal server operations a software error might be the cause If you suspect a software problem refer to the information that comes with the software package Viewing the test log The test l...

Страница 24: ...m board 3 Place a jumper on pins 1 and 2 to enable BIOS recovery mode 4 Insert the BIOS flash diskette into the diskette drive 5 Restart the server The Recovery Boot screen will appear A progress repo...

Страница 25: ...e Ethernet Transmit Receive Activity light illuminates when the Ethernet controller sends or receives data over the Ethernet Network If the Ethernet Transmit Receive Activity light is off make sure th...

Страница 26: ...e that the hub is turned on Check all connections at the Ethernet controller and the hub Check the cable A crossover cable is required unless the hub has an X designation Use another port on the hub I...

Страница 27: ...program Although interrupt sharing is allowed for PCI devices some devices do not function well when they share an interrupt with a dissimilar PCI device Try changing the IRQ assigned to the Ethernet...

Страница 28: ...at the adapter is seated correctly If the adapter is seated correctly go to Starting the diagnostic programs on page 14 to run the diagnostic programs PCNTNW NW 072 A resource tag is unavailable Expla...

Страница 29: ...d only as a destination address it cannot be used as a source address You tried to enter a source address with this bit set The driver cleared the group bit of the source address Action None necessary...

Страница 30: ...e Protocol Manager Explanation TheNDISstackisnotconfiguredcorrectlyinthePROTOCOL INIfile Action Check and correct your configuration PCNTND 9 Cannot find the PROTOCOL INI entry Explanation TheNDISstac...

Страница 31: ...on Setup Utility program PCNTND 25 PCI scan specified PCI bus not found Explanation The driver cannot locate the PCI bus Action Run the diagnostic programs PCNTND 29 WARNING DMA number is not necessar...

Страница 32: ...gs pnt0 7 Cannot allocate memory for the adapter during reset Please check your Streams parameters Explanation The system is out of Streams memory blocks Action Use the CRASH utility to increase the n...

Страница 33: ...Ethernet controller pnt0 22 add_intr_handler failed Out of range IPL Explanation The interrupt request IRQ that was specified or the IRQ that was found conflicts with other devices in the server Acti...

Страница 34: ...he battery IBM has designed this product with your safety in mind The lithium battery must be handled correctly to avoid possible danger If you replace the battery you must adhere to the following ins...

Страница 35: ...sert the new battery a Tilt the battery so that you can insert it into the socket under the battery clip b As you slide it under the battery clip press the battery down into the socket 5 Reinstall the...

Страница 36: ...nutes while the server is operating A removed hot swap drive is replaced within two minutes of removal Cables for optional adapters are routed according to the instructions provided with the adapters...

Страница 37: ...Guide CDs also contain a collection of application programs which you can install after your server is up and running See Server features on page 5 for more detailed information ServeRAID programs The...

Страница 38: ...ar on this summary screen You cannot edit the fields This choice appears on both the full and limited Configuration Setup Utility menus System Information Select this choice to display information abo...

Страница 39: ...clock time leave the value set at its default of 0 System Security Select this choice to set passwords or a system owner s name This choice appears only on the full Configuration Setup Utility main m...

Страница 40: ...in the master boot record at startup You also can choose to run POST in the enhanced mode or the quick mode Advanced Setup Select this choice to change values for advanced hardware features such as ca...

Страница 41: ...er turning the server off and on three times results in a default startup that enables video again Memory Settings Select this choice to manually disable or enable a bank of memory If a memory error i...

Страница 42: ...d mouse but allows the system to start the operating system The keyboard and mouse remain locked until you enter the correct password You can use any combination of up to seven characters A Z a z and...

Страница 43: ...0 and connect all external cables and power cords Note You can now start the Configuration Setup utility program and change the power on password If you want the server to ask for a password when you...

Страница 44: ...select a choice from the menu Press Esc to return to the previous menu Press the F5 key to switch between color and monochrome modes if your monitor permits 5 Follow the instructions on the screen to...

Страница 45: ...make updates you must know the ID of the device whose parameters you want to configure Note The Maximum Sync Transfer Rate represents the transfer rate for Ultra SCSI devices The transfer rate for Ult...

Страница 46: ...acing a failing hard disk drive Note If your server has a PCI RAID adapter installed refer to the RAID adapter documentation for instructions for performing low level formats on hard disk drives attac...

Страница 47: ...hile the system is running provided that your system is configured to support this function For complete information about installing or removing a hot swap or hot plug component see the information p...

Страница 48: ...rs The following illustration shows a layout of the system board and identifies system board connectors for user installable options 1 PCI slot 5 32 bit J44 2 Battery 3 PCI slot 4 32 bit J39 4 PCI slo...

Страница 49: ...hannel B J17 3 Fan 3 J35 4 Main Power J4 5 Power J51 6 Fan 1 J59 7 3 3V power for optional backplane J52 8 Power system management J12 9 DASD SCSI system management J5 10 Fan 2 J60 11 Operator informa...

Страница 50: ...lel port J22 2 Video Advanced System Management Process or port J13 3 USB ports J11 4 Ethernet ports J9 5 Keyboard mouse port J6 6 Serial ports J3 System board switches and jumpers The following illus...

Страница 51: ...switches 1 8 As shown in this illustration switch 8 is at the top of the switch block and switch 1 is at the bottom The following table describes each switch Table 7 Switches 1 8 Switch number Descrip...

Страница 52: ...with the server 1 Secondary microprocessor failure CR7 2 Primary microprocessor failure CR1 3 Voltage regulator module VRM2 failure CR16 4 Integrated voltage regulator VRM1 failure CR4 8 Password ove...

Страница 53: ...his function For complete details about installing or removing a hot swap or hot plug component see the information provided in this chapter The blue color on components and labels indentifies touch p...

Страница 54: ...provided with the adapters A failed fan is replaced within 48 hours Working inside a server with power on Your server supports hot plug hot add and hot swap devices and it is designedto operate safel...

Страница 55: ...Flanges To remove the server top cover 1 Review the information in Before you begin on page 45 2 If you are planning to install or remove any part other than a hot swap hard disk drive hot swap power...

Страница 56: ...following illustration shows the location of the PCI expansion slots on the system board 1 PCI slot 5 64 bit J44 2 PCI slot 4 64 bit J39 3 PCI slot 3 64 bit J34 4 PCI slot 2 32 bit J32 5 PCI slot 1 32...

Страница 57: ...and 5 are on secondary PCI bus B The system scans PCI slots 1 through 5 to assign system resources then the system starts boots the PCI devices in the following order if you have not changed the boot...

Страница 58: ...e the adapter component side up on a flat static protective surface 8 Set any jumpers or switches as described by the adapter manufacturer 9 Install the adapter a Carefully grasp the adapter by its to...

Страница 59: ...es are installed in bays Your server comes with a preinstalled diskette drive and a preinstalled CD ROM drive 1 CD ROM drive 2 Diskette drive 3 How swap bay SCSI ID 2 4 How swap bay SCSI ID 0 5 How sw...

Страница 60: ...the empty 5 25 inch bays to the SCSI channel A connector on the system board SCSI IDs Each SCSI device that is connected to an individual channel of a SCSI controller needs a unique identification ID...

Страница 61: ...he filler panel and pulling it away from the server 3 Install the hard disk drive in the hot swap bay a Ensure the tray handle is open that is perpendicular to the drive b Align the drive tray assembl...

Страница 62: ...in the bay Note The server s EMI integrity and cooling are protected by having the non hot swap bays covered or occupied When you install a drive save the filler panel from the bay in case you later r...

Страница 63: ...rop IDE cable that comes with the option Note If you add an IDE device such as a CD ROM R W drive or a DVD ROM drive you will no longer be able to use the slim high CD ROM that came with the system a...

Страница 64: ...mes the application processor Attention To avoid damage and ensure proper server operation when you install a new or an additional microprocessor use microprocessors that have the same cache size and...

Страница 65: ...sor connector and carefully press the microprocessor into the connector Note To remove a microprocessor pull upward on the microprocessor handle 6 Install the VRM included in the microprocessor kit At...

Страница 66: ...tact a service technician 1 Power supply 1 power cord connector 2 Power supply 2 power cord connector 1 Filler panel 2 Power supply 3 Handle 4 AC Power light 5 DC Power light To install a power supply...

Страница 67: ...power to the server to replace a hot swap fan assembly Attention Replace a fan that has failed within 48 hours to help ensure proper cooling 1 Handle 2 Fan 3 3 Fan 1 4 Fan 2 Error LED 5 Fan 2 To repl...

Страница 68: ...il it clicks into place To complete the installation If you disconnected any cables from the back of the server reconnect the cables then plug the power cords into properly grounded electrical outlets...

Страница 69: ...ID Installation procedure To attach an external device 1 Turn off the server and all attached devices 2 Follow the instructions that come with the option to prepare it for installation and to connect...

Страница 70: ...ce appears only on the full configuration menu If you set two levels of passwords you must enter the administrator password to access the full configuration menu 3 From the main menu select Devices an...

Страница 71: ...r of your server 9 I O Data 7 Data 7 10 I ACK ACK 11 I BUSY WAIT 12 I PE paper end PE paper end 13 I SLCT select SLCT select 14 O AUTO FD feed AUTO FD 15 I ERROR ERROR 16 O INIT INIT 17 O SLCT IN SLCT...

Страница 72: ...ice pointing device port The system board has one auxiliary device port that supports a mouse or other pointing device The following table shows the pin number assignments for the auxiliary device con...

Страница 73: ...must move the SCSI cable from the system board SCSI connector to an internal channel connector on the RAID adapter SCSI cabling requirements If you plan to attach external SCSI devices you must order...

Страница 74: ...13 36 Data 13 3 Data 14 37 Data 14 4 Data 15 38 Data 15 5 Data P1 39 Data P1 6 Data 0 40 Data 0 7 Data1 41 Data 1 8 Data 2 42 Data 2 9 Data 3 43 Data 3 10 Data 4 44 Data 4 11 Data 5 45 Data 5 12 Data...

Страница 75: ...main menu select Devices and I O Ports then press Enter Note The Device and I O Ports choice appears only on the full configuration menu If you set two levels of passwords you must enter the administ...

Страница 76: ...d a 4 pin cable to connect devices to USB 1 or USB 2 If you plan to attach more than two USB devices you must use a hub to connect the devices The hub provides multiple connectors for attaching additi...

Страница 77: ...gment as the primary Ethernet controller you can configure the server to support a failover function You can configure either the integrated Ethernet controller or the NIC adapter as the primary Ether...

Страница 78: ...LOG file when a failover occurs a Copy the file PCNETOS2 EXE from the root directory of the diskette that is created using the ServerGuide CDs to your hard disk drive b Add the following statement to...

Страница 79: ...il the program is installed 7 Restart the server To install the IBM PCI Hot Plug Solution package 1 Download the IBM PCI Hot Plug Services EXE file from the Netfinity Support web page and extract the...

Страница 80: ...Enable for DMI Hot Swap Support checkbox is checked a DMI alert will also be generated IntraNetWare 1 Add the redundant NIC adapter according to the instructions that are provided with the adapter 2...

Страница 81: ...RJ 45 connector You can attach a dedicated modem to the D shell system management connector on the rear of your server to communicate with the integrated Netfinity Advanced System Management Processo...

Страница 82: ...ctor 2 Serial A 3 Mouse 4 Universal serial bus USB 1 and 2 5 Management port C 6 Parallel 7 Video 8 Ethernet 9 Cable management arm 10 Keyboard 11 Serial B 12 Power supply 2 power cord connector Refer...

Страница 83: ...ager for Web Netfinity Manager for Web enables access and remote control of the Netfinity Manager system over the Internet using any system that has an Internet connection and a World Wide Web WWW bro...

Страница 84: ...quired for Netfinity Manager with Web Enhancement NetBIOS Note The Netfinity Manager NetBIOS requirements are three names two sessions and nine network control blocks NCBs IPX SNA IBM Communications M...

Страница 85: ...anager for Windows NT system requirements The minimum system requirements for Netfinity Manager for Windows NT are Microsoft Windows NT version 4 0 or later Approximately 17 MB 20 MB of hard disk spac...

Страница 86: ...etter and then press Enter b Type SCOS2 and then press Enter The ServerGuide Netfinity Applications windows opens c Select IBM Netfinity Manager from the Available Applications selection list Note To...

Страница 87: ...Connection Manager will be installed instead of Serial Connection Control For more information on Advanced System Management and the Dynamic Connection Manager service see the Advanced System Managem...

Страница 88: ...Manager System Information Tool System Monitor System Partition Access requires System Partition Update Connector Manager available only on systems running Windows NT 4 0 or later System Profile Web...

Страница 89: ...ique it can prevent remote Netfinity Manager users from using the Serial Connection Control service to access the system c Enable the Network Driver When you have entered all required information clic...

Страница 90: ...ems and will not attempt to resolve the numeric address into an alphanumeric Domain Name Server DNS address for example your system ibm com Select this option if you are using Netfinity Manager is a W...

Страница 91: ...ger Software Inventory System Information Tool System Profile System Monitor Information on how to install and configure support for database export follows If support for DB2 database export is being...

Страница 92: ...inding the database refer to Activating the database Installing the database on OS 2 1 Insert the Netfinity Manager CD into the CD ROM drive in this example drive D individual drive letters might be d...

Страница 93: ...If you are not connected to the DB2 Netfinity database connect to the database now 2 Type the following command DB2 GRANT privilegecode ON TABLE tablename TO userid where privilegecode is one of the f...

Страница 94: ...D id PUBLIC DBNAME databasename PRIV privilegecode where id is the user ID to be granted access databasename is the name of the database as specified during NETFINDB execution privilegecode is one of...

Страница 95: ...database as specified during NETFINDB execution 5 Press Enter To configure Netfinity Manager to discontinue export data through ODBC for use on DB2 refer to ODBC database support on page 89 Lotus Note...

Страница 96: ...ew to create the database and close the New Database window 10 Double click the Netfinity Database icon in the Lotus Notes workspace 11 Click Database in the File pull down menu 12 Click Access Contro...

Страница 97: ...al additional information These items are identified by a plus sign in the left side border of the Notes window beside the name of the data item To expand the data item select the item and then click...

Страница 98: ...g the ODBC database a Open Services from the Control Panel b Click Netfinity Support Program from the Services field then click Startup c Click Automatic in the Startup Type button group d Click This...

Страница 99: ...en the Database Server window 4 Select the database within which the table groups will be created 5 Click OK The Netfinity Manager Database Access window opens 6 Type in the User ID field netfin netfi...

Страница 100: ...ity Manager database support on page 83 ODBC IBM DB2 Universal Database 5 0 Yes DB2 Driver Yes DB2 Driver Yes DB2 Driver Yes DB2 Driver Yes DB2 Driver ODBC Microsoft SQL Version 7 0 Yes Microsoft SQL...

Страница 101: ...The service GUIs when functioning along with their respective base program enable access to the service Some services are available only on systems with certain system configurations These services ar...

Страница 102: ...Alert on LAN configuration Use the Alert on LAN configuration service to configure monitoring options of Alert on LAN capable systems locally and remotely Systems with Alert on LAN capability provide...

Страница 103: ...Netfinity Manager system has start up problems enabling you to react quickly to problems and minimize downtime Predictive Failure Analysis The Predictive Failure Analysis PFA service enables continual...

Страница 104: ...nd displays it on the screen These snapshots can be saved as bitmaps and viewed later Security Manager The Security Manager service can prevent unauthorized access to some or all of the Netfinity Mana...

Страница 105: ...enormous data files This service is available for both stand alone and network use System Partition Access The System Partition Access allows for greatly simplified system partition file handling both...

Страница 106: ...utton click the Netfinity Manager Network Interface object This will open the Netfinity Manager Network Interface context menu 4 Click Settings to open the Netfinity Manager Network Interface Settings...

Страница 107: ...a source directory for a Netfinity Manager installation 1 Create a new directory on your system This new directory will serve as a source directory for the program files Important Be sure to copy the...

Страница 108: ...h comments on the included parameters S drive path Specifies the drive and path to install from This is the directory to which the files were copied T drive Specifies the drive to install to Default i...

Страница 109: ...cpip Netfinity Manager CD for Windows 95 NT NetFinity Admin NULL Manager CL 0 1 NETFBASE EXE CCL 0 1 NETDOM INI CCL 0 1 NETNODES INI CCL 0 1 INSTALL BAT CCL 0 1 NETFINST EXE CCL 0 1 INSTALL INI CCL 0...

Страница 110: ...ine In most cases it should be the reserved string NULL The easiest way to customize an installation is to simply put a semicolon in front of any service that you want to remove from the installation...

Страница 111: ...ote Before performing any removals read Safety information on page 141 and Before you begin on page 45 Removing the LED cover 1 Front LED cover 2 Tabs To remove the LED cover do the following 1 Remove...

Страница 112: ...moving the cover and bezel on page 47 2 Disconnect the cables from the system board 3 Remove the screw 2 4 Gently pull off the board 1 Removing the diskette CDROM drive 1 Screw 2 12 7MM Diskette CDROM...

Страница 113: ...crews 2 To remove the LED board 1 Remove the cover See Removing the cover and bezel on page 47 2 Disconnect the LED board cable from the system board 3 Remove the two screws 2 4 Carefully slide out th...

Страница 114: ...Removing the hot swap hard disk drive backplane 1 Backplane bracket 2 Backplane board 3 Screws 4 To remove the hot swap hard disk drive backplane 1 Remove the cover See Removing the cover and bezel o...

Страница 115: ...lastic retainer To remove the power supply backplane 1 Remove the cover See Removing the cover and bezel on page 47 2 Remove power supplies from the backplane 1 3 Disconnect cables from the backplane...

Страница 116: ...r See Removing the cover and bezel on page 47 2 Remove screw 1 3 Pull the AC distribution box 2 toward front of machine in order to release it from the chassis clips 3 4 Remove the two hot swap power...

Страница 117: ...o remove the system board 1 Remove the cover See Removing the cover and bezel on page 47 2 Remove the rear air flow fan 3 Remove the air cover 4 Remove the system board cables 5 Pull up on the two kno...

Страница 118: ...110 Hardware Maintenance Manual Netfinity 4500R Type 8656...

Страница 119: ...llowing examples Note One beep after successfully completing POST indicates the system is functioning properly Beeps Description 1 2 3 One beep A pause or break Two beeps A pause or break Three Beeps...

Страница 120: ...ation failed 1 Battery 2 System Board 2 3 1 Screen initialization failed 1 Jumper on J14 2 System Board 2 3 2 Screen memory failed 1 System Board 2 3 3 Screen retrace failed 1 System Board 2 3 4 Searc...

Страница 121: ...reseat the memory modules then do a 3 boot reset See Using the Configuration Setup Utility program on page 29 2 DIMMs 3 Memory Board 4 System Board Two Short Beeps Information only the configuration h...

Страница 122: ...Action No beep and the system operates correctly 1 Check speaker cables 2 Speaker 3 System Board No Beeps occur after successfully completing POST The Power On Status is disabled 1 Run Configuration S...

Страница 123: ...fan 3 Fan Cable 4 System Board 5 Power Backplane Board MEM LED on The LED next to the failing DIMM is on 1 DIMM 2 Failing DIMM in slot J1 J4 NMI LED on 1 Reboot the system 2 Check the System Error Log...

Страница 124: ...ecommended temperature 1 Information LED Panel 2 System Board b DASD over recommended temperature DASD LED also on 1 Overheating hard drive 2 DASD Backplane 3 System Board c System over recommended te...

Страница 125: ...Board 020 XXX 004 Failed Hot Swap Slot 4 PCI Latch test 1 PCI Hot Swap Latch Assembly 2 System Board 030 XXX 000 Failed Internal SCSI interface test 1 System Board 035 XXX 099 1 No adapters were found...

Страница 126: ...gnostics LED Panel 2 Power Switch 3 Assembly 180 XXX 003 Failed System Board LED test 1 System Board 180 XXX 004 Failed System Board LED test 1 System Board 180 XXX 005 Failed SCSI Backplane LED test...

Страница 127: ...refers to the RAID logical array 1 Fixed Disk 5 264 XXX 0NN Failed Tape Drive test 1 Tape Cartridge if user executed the Read Write Tape Drive test failure code of XXX 256 2 SCSI or Power Cable connec...

Страница 128: ...er clip into the manual tray release opening 2 Run CD ROM diagnostics 3 CD ROM Drive CD ROM drive is not recognized 1 Run Configuration Setup enable primary IDE channel 2 Check cables and jumpers 3 Ch...

Страница 129: ...rive is enabled in the Configuration Setup utility program b The diskette is good and not damaged Try another diskette if you have one c The diskette is inserted correctly in the drive d The diskette...

Страница 130: ...nd disconnect the cables and power connectors to all internal and external devices Power on the system If the DC Good LED comes on replace the adapters and devices one at a time until you isolate the...

Страница 131: ...re error 1 System Board 176 Computer cover or cable cover was removed without a key being used 1 Run Configuration Setup 2 System Board 3 C2 Security Switch 177 178 Security hardware error 1 Run Confi...

Страница 132: ...IMM if not disabled by user 301 Keyboard or keyboard controller error 1 Keyboard 2 System Board 303 Keyboard controller error 1 System Board 602 Invalid diskette boot record 1 Diskette 2 Diskette Driv...

Страница 133: ...3 System Board 1304 I2 C cable to diagnostic LED board not found 1 Power Switch Assembly 2 System Board 1600 The Service Processorisnotfunctioning Do the following before replacing a FRU 1 Ensure that...

Страница 134: ...ed 2 Run Diagnostics 3 Hard Disk Drive 4 SCSI Backplane 5 Cable 6 System Board 2400 Video controller test failure 1 Video Adapter if installed 2 System Board 2462 Video memory configuration error 1 Vi...

Страница 135: ...o PCI bridge error 1 Run Configuration Setup 2 Move the failing adapter to slot 1 or 2 3 Failing Adapter 4 System Board 00180700 00180800 General PCI error 1 System Board 2 PCI Card 01295085 ECC check...

Страница 136: ...power on the server 2 The cables for all external SCSI devices are connected correctly 3 If you have attached an external SCSI device to the server make sure the external SCSI termination is set to a...

Страница 137: ...mmended temperature level warning system board is under recommended temperature 1 Ambient temperature must be within normal operating specifications see Features and specifications on page 3 System ov...

Страница 138: ...ed X current level non critical system running too much current on that voltage 1 See Power checkout on page 26 System running non redundant power level non critical system does not have redundant pow...

Страница 139: ...ritical system drawing too much current on voltage X bus 1 See Power checkout on page 26 System shutoff due to X currentunder min value level critical current on voltage bus X under minimum value 1 Se...

Страница 140: ...recommended operating range 1 Ensure system is being properly cooled see Temperature checkout on page 27 System shutoff due to high ambient temperature level critical high ambient temperature 1 Ambien...

Страница 141: ...IBM devices Each adapter Drives Memory Modules Minimum requirement 128 MB 4x128 MB DIMMs Note Minimum operating requirements are a 1 Power Supply b Power Backplane c System Board d 1 Microprocessor an...

Страница 142: ...1 If the problem goes away when you remove an adapter from the system and replacing that adapter does not correct the problem suspect the System Board 2 If you suspect a networking problem and all th...

Страница 143: ...r Assembly All Models 00N7259 6 9 1 GB Hard Disk Drive 7200 RPM 37L6212 6 18 2 GB Hard DIsk Drive 7200 RPM 37L6213 6 9 1 GB Hard Disk Drive 10000 RPM 37L6216 6 18 2 GB Hard Disk Drive 10000 RPM 37L621...

Страница 144: ...affle Air All Models 00N7172 20 Rear Fan Assembly 92MM X 38 00N7248 24X TEAC CDROM Alternate All Models 19K1523 Power Backplane Insulator All Models 00N7188 Card Assembly Front LED Card Baldplate All...

Страница 145: ...er PWR BP to IO Planar 2X12 All Models 37L0354 Cable Power Power Backplane to SCSI Backplane Media Bays 5 Drop All Models 37L0358 Power Cord All Models 6952301 Cable Signal LVD SCSI Jumper Repeater to...

Страница 146: ...a 12J5987 Afghanistan Algeria Andorra Angola Austria Belgium Benin Bulgaria Burkina Faso Burundi Cameroon Central African Rep Chad Czech Republic Egypt Finland France French Guiana Germany Greece Guin...

Страница 147: ...Parts listing Type 8656 139...

Страница 148: ...140 Hardware Maintenance Manual Netfinity 4500R Type 8656...

Страница 149: ...that you think are too heavy for you Do not perform any action that causes hazards to the customer or that makes the equipment unsafe Before you start the machine ensure that other service representa...

Страница 150: ...hen operate the switch or unplug the power cord quickly Do not work alone under hazardous conditions or near equipment that has hazardous voltages Disconnect all power before Performing a mechanical i...

Страница 151: ...ent occurs Use caution do not become a victim yourself Switch off power Send another person to get medical aid Safety inspection guide The intent of this inspection guide is to assist you in identifyi...

Страница 152: ...he machine the part the work mat and the person handling the part are all at the same charge Notes 1 Use product specific ESD procedures when they exceed the requirements noted here 2 Make sure that t...

Страница 153: ...translations for that caution statement appear in this section under statement 1 Be sure to read all caution and danger statements before performing any of the instructions Statement 1 DANGER Electri...

Страница 154: ...ir or disassemble Dispose of the battery as required by local ordinances or regulations Statement 3 CAUTION When laser products such as CD ROMs DVD ROM drives fiber optic devices or transmitters are i...

Страница 155: ...exposure to the beam Statement 4 CAUTION Use safe practices when lifting Statement 5 CAUTION The power control button on the device and the power switch on the power supply do not turn off the electri...

Страница 156: ...148 Hardware Maintenance Manual Netfinity 4500R Type 8656 Statement 10 CAUTION Do not place any object weighing more than 82 kg 180 lbs on top of rack mounted devices 1 2...

Страница 157: ...el tricas corretamente instaladas e aterradas Conecte todos os equipamentos ao qual esse produto ser conectado a tomadas corretamente instaladas Sempre que poss vel utilize apenas uma das m os para c...

Страница 158: ...onserte nem desmonte Para descartar a bateria entre em contato com a rea de atendimento a clientes IBM pelo telefone 011 889 8986 para obter informa es sobre como enviar a bateria pelo correio para a...

Страница 159: ...UIDADO Ao levantar a m quina fa a o com seguran a Instru o 5 CUIDADO Os bot es Liga Desliga localizados no dispositivo e na fonte de alimenta o n o desligam a corrente el trica fornecida ao dispositiv...

Страница 160: ...152 Hardware Maintenance Manual Netfinity 4500R Type 8656 CUIDADO N o coloque nenhum objeto com peso superior a 82 kg 180 lbs sobre dispositivos montados em rack...

Страница 161: ...Related service information 153...

Страница 162: ...154 Hardware Maintenance Manual Netfinity 4500R Type 8656...

Страница 163: ...Related service information 155...

Страница 164: ...156 Hardware Maintenance Manual Netfinity 4500R Type 8656...

Страница 165: ...Related service information 157...

Страница 166: ...158 Hardware Maintenance Manual Netfinity 4500R Type 8656...

Страница 167: ...Related service information 159...

Страница 168: ...160 Hardware Maintenance Manual Netfinity 4500R Type 8656...

Страница 169: ...ise de courant correctement c bl s tout quipement connect ce produit Lorsque cela est possible n utilisez qu une seule main pour connecter ou d connecter les c bles d interface Ne mettez jamais un qui...

Страница 170: ...100 C Ne cherchez pas la r parer ou la d monter Pour la mise au rebut reportez vous la r glementation en vigueur Notice n 3 ATTENTION Si des produits laser sont install s tels que des unit s de CD RO...

Страница 171: ...ulever ce produit Notice n 5 ATTENTION Le bouton de mise sous tension hors tension de l unit et l interrupteur d alimentation du bloc d alimentation ne coupent pas l arriv e de courant lectrique l int...

Страница 172: ...164 Hardware Maintenance Manual Netfinity 4500R Type 8656 ATTENTION Ne posez pas d objet dont le poids d passe 82 kg sur les unit s mont es en armoire...

Страница 173: ...enen Ger te ebenfalls an Schutzkontaktsteckdosen mit ordnungsgem geerdetem Schutzkontakt anschlie en Signalkabel m glichst einh ndig anschlie en oder l sen Keine Ger te einschalten wenn die Gefahr ein...

Страница 174: ...estimmungen f r die Entsorgung von Sonderm ll beachten Hinweis 3 ACHTUNG Wenn ein Laserprodukt z B CD ROM Laufwerke DVD Laufwerke Einheiten mit Glasfaserkabeln oder Transmitter installiert ist beachte...

Страница 175: ...Sicherheitsbestimmungen beachten Hinweis 5 ACHTUNG Mit dem Betriebsspannungsschalter an der Vorderseite des Servers und dem Betriebsspannungsschalter am Netzteil wird die Stromversorgung f r den Serv...

Страница 176: ...168 Hardware Maintenance Manual Netfinity 4500R Type 8656 ACHTUNG Keine Gegenst nde die mehr als 82 kg wiegen auf Rack Einheiten ablegen...

Страница 177: ...ita di terra di sicurezza Collegare qualsiasi apparecchiatura collegata a questo prodotto ad una presa elettrica correttamente cablata e munita di terra di sicurezza Quando possibile collegare o scoll...

Страница 178: ...uperiore ai 100 C Cercare di ripararla o smontarla Smaltire secondo la normativa in vigore D Lgs 22 del 5 2 9 e successive disposizioni nazionali e locali Avviso 3 ATTENZIONE Quando si installano prod...

Страница 179: ...ire delle norme di sicurezza Avviso 5 ATTENZIONE Il pulsante del controllo dell alimentazione situato sull unit e l interruttore di alimentazione posto sull alimentatore non disattiva la corrente elet...

Страница 180: ...172 Hardware Maintenance Manual Netfinity 4500R Type 8656 ATTENZIONE Non poggiare oggetti che pesano pi di 82 kg sulla parte superiore delle unit montate in rack...

Страница 181: ...Related service information 173...

Страница 182: ...174 Hardware Maintenance Manual Netfinity 4500R Type 8656...

Страница 183: ...Related service information 175...

Страница 184: ...conexi n a tierra y cableado correctos Conecte a tomas de alimentaci n con un cableado correcto cualquier equipo que vaya a estar conectado a este producto Si es posible utilice una sola mano cuando...

Страница 185: ...Arrojarla al agua o sumergirla Calentarla a una temperatura que supere los 100 C 212 F Repararla o desmontarla Despr ndase de la bater a siguiendo los requisitos que exija el reglamento o la legislaci...

Страница 186: ...raci n 4 PRECAUCI N Tome medidas de seguridad al levantar el producto Declaraci n 5 PRECAUCI N El bot n de control de alimentaci n del dispositivo y el interruptor de alimentaci n de la fuente de alim...

Страница 187: ...Related service information 179 PRECAUCI N No coloque ning n objeto que pese m s de 82 kg 180 libras encima de los dispositivos montados en bastidor...

Страница 188: ...____________________________________ ________________________________________________________________ 2 What would you like to see added changed or deleted in this manual _____________________________...

Страница 189: ...ave the same BIOS level 3 Have the same adapters attachments in the same locations 4 Have the same address jumpers terminators cabling 5 Have the same software versions and levels 6 Have the same Refe...

Страница 190: ...rks of other companies MMX and Pentium are trademarks or registered trademarks of Intel Corporation UNIX is a trademark or registered trademark of The Open Group in the United States and other countri...

Страница 191: ......

Страница 192: ...IBM Part Number 10K2616 File Number Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber 10K2616 0410K2616...

Отзывы: