![IBM IntelliStation M Pro 9229 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/ibm/intellistation-m-pro-9229/intellistation-m-pro-9229_installation-manual_4065488038.webp)
Table
2.
POST
error
messages
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
part
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
codes
Description
Action
162
A
change
in
the
device
configuration
occurred.
This
error
occurs
under
one
or
more
of
the
following
conditions:
v
A
new
device
has
been
installed.
v
A
device
has
been
moved
to
a
different
location
or
cable
connection.
v
A
device
has
been
removed
or
disconnected
from
a
cable.
v
A
device
is
failing
and
is
no
longer
recognized
by
the
computer
as
being
installed.
v
An
external
device
is
not
turned
on.
v
An
invalid
checksum
is
detected
in
the
battery-backed
memory.
1.
Make
sure
that
all
external
devices
are
turned
on.
You
must
turn
on
external
devices
before
you
turn
on
the
computer.
2.
If
you
did
not
add,
remove,
or
change
the
location
of
a
device,
a
device
is
probably
failing.
Running
the
diagnostic
program
might
isolate
the
failing
device.
(See
“Running
the
diagnostic
programs,”
“Viewing
the
test
log,”
or
“Using
the
Enhanced
Diagnostics
diskette
or
CD”
in
the
Problem
Determination
and
Service
Guide
).
3.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
4.
Reseat
the
following
components:
a.
Battery
b.
Failing
device
5.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Battery
b.
Failing
device
(if
the
device
is
a
FRU,
the
device
must
be
replaced
by
a
trained
service
technician
only)
c.
(Trained
service
technician
only)
System
board
163
The
time
of
day
has
not
been
set.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
make
sure
that
the
date
and
time
are
correct,
and
save
the
settings.
2.
Reseat
the
battery.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
26
IBM
IntelliStation
M
Pro
Type
9229:
Installation
Guide
Содержание IntelliStation M Pro 9229
Страница 3: ...IBM IntelliStation M Pro Type 9229 Installation Guide ...
Страница 26: ...14 IBM IntelliStation M Pro Type 9229 Installation Guide ...
Страница 34: ...22 IBM IntelliStation M Pro Type 9229 Installation Guide ...
Страница 60: ...48 IBM IntelliStation M Pro Type 9229 Installation Guide ...
Страница 71: ......
Страница 72: ... Part Number 40K2288 Printed in USA 1P P N 40K2288 ...