Table
2.
POST
error
messages
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
part
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
codes
Description
Action
101
Timer
tick
interrupt
failure.
(Trained
service
technician
only)
Replace
the
system
board.
102
Timer
tick
2
test
failure.
(Trained
service
technician
only)
Replace
the
system
board.
151
A
real-time
clock
(RTC)
error
occurred.
1.
Run
the
diagnostics
program.
2.
Reseat
the
battery.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
161
The
real-time
clock
battery
has
failed.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
make
sure
that
the
date
and
time
are
correct,
and
save
the
settings.
2.
Reseat
the
battery.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
Chapter
5.
Solving
problems
25
Содержание IntelliStation M Pro 9229
Страница 3: ...IBM IntelliStation M Pro Type 9229 Installation Guide ...
Страница 26: ...14 IBM IntelliStation M Pro Type 9229 Installation Guide ...
Страница 34: ...22 IBM IntelliStation M Pro Type 9229 Installation Guide ...
Страница 60: ...48 IBM IntelliStation M Pro Type 9229 Installation Guide ...
Страница 71: ......