Once SCM is started, follow these steps to add your RSSMs to the interface:
•
Sign on with a local Windows ID and password. You are not signing onto the RSSMs yet
•
Expand
BC-S SAS RAID Module
and then
Health
•
Click
All Resources
•
Click
Add
SAS RAID Modules
•
Enter the IP address of the SAS switch component of the RSSM in I/O bay 3
o
Both the SAS switch and the RAID subsystem in both RSSMs must have
external IP addresses assigned. See section 3.10.1 for instructions
•
Enter an ID and password for both the SAS switch and the RAID subsystem of the RSSM
in I/O bay 3
o
The defaults for the SAS switch are USERID and PASSW0RD
o
The defaults for the RAID subsystem are USERID1 and PASSW0RD
•
Optionally, enter a nickname for these RSSMs
•
Click
OK
In most cases, it is not necessary to create a custom SAS zone configuration. If you do need to
create one, use the steps immediately below (otherwise, skip to the next set of bullets):
•
Use the radio button to select the SAS switch in bay 3
•
In the drop-down menu above, select
Configuration
, then
SAS Zoning…
•
Follow the instructions in chapter 4.4 of the Redpiece
Implementing the IBM BladeCenter
S Chassis
(REDP-4357), available here:
http://www.redbooks.ibm.com/abstracts/redp4357.html?Open
To create the RAID array and LUN configuration, follow these steps:
•
On
the
All Resources
screen, select the RAID subsystem
•
In the drop-down menu above, select
Configuration
, then
Storage…
•
Click
the
Storage Pools
tab. Storage pools are the RAID arrays you can create in the
chassis using the RSSM
•
Click
Create Storage Pool…
•
Select
Manually choose drives (advanced)
and click
Next
•
Select the correct SAS drives (preferably in both DSMs) and RAID level for this storage
pool, then click
Next
•
Create the correct number of LUNs (volumes) with the correct capacity and add them to
the list of new volumes. Then click
Next
•
All blades that contain a CFFv or CIOv SAS expansion card and are allowed to access
the RAID subsystem will be identified in the
Select Hosts
area
o
If your blade is not identified, click
Discover Hosts
o
If the blade still does not appear, check the SAS zoning configuration and
whether the SAS adapter on the blade is installed and operational
•
Click your blade in the
Select Hosts
area
•
Click on all LUNs that should be attached to that blade in the
Select Volumes
area
•
Click
Map Volumes
. This action will map the selected LUNs to both ports on the SAS
expansion card. The maximum number of LUNs per blade is 8
•
Click
Next
and then
Finish
If VIOS is already running on the blade, use the
cfgdev
command on the VIOS command line to
recognize the new LUNs.