3.
On the front panel display, select
Eth0 Config
and select
DHCP
.
4.
On the next pane, use the
↓
to confirm the setting. The system restarts automatically. The final pane
displays the IP address that is assigned by the DHCP server.
Results
If the network fails to start, check the Ethernet connection and contact your system administrator. If the
IP configuration was successfully saved, select
Restart Net
from the management controller menu instead
of reselecting the same IP configuration.
Connecting to the web management interface
Learn about the tasks you need to perform to connect to the web management interface.
Acquiring the system IP address
To use the web interface, you must connect to it over your network.
About this task
To acquire the IP address of the storage system, complete the following steps by using the front panel
display:
Procedure
1.
Press the
Menu
button to display the
Main Menu
pane. Use the arrow buttons to find the
System
Info
option, and then press
Select
.
2.
Use the
↓
button to scroll until you see the
Eth0 P
line and the lines below it.
3.
Take note of the IP address.
Accessing the web interface
Learn to how to access the storage system web interface.
About this task
To open the web interface, complete the following steps:
Procedure
1.
Using a web browser that can run Java
™
, enter the system IP address as
http://xxx.xxx.xxx.xxx
. The
System Login pane is shown. The storage system is initially configured with a default admin user
defined as
User: admin
and
Password: password
.
2.
Log in to the system. The Web Interface Opening pane is shown.
3.
To work with the web interface, you can expand or select the storage system icon in the system tree.
Reformatting uninitialized flashcards
If the storage system has been without power for more than one month, it is possible that the
management GUI shows one or more flashcards as failed. The front panel may also show error messages
such as Storage Offline.
Before you begin
This condition is NOT a failure. It is a characteristic of Enterprise Flash technologies that are used in the
storage system. The remedy is to format the flash array. There is no immediate need to contact support if
this condition is observed on first boot or if the storage system was powered off for more than one
Installing the IBM FlashSystem 810
9
Содержание FlashSystem 810
Страница 1: ...IBM FlashSystem Installing the IBM FlashSystem 810 GI11 9894 04...
Страница 2: ......
Страница 3: ...IBM FlashSystem Installing the IBM FlashSystem 810 GI11 9894 04...
Страница 6: ...iv IBM FlashSystem Installing the IBM FlashSystem 810...
Страница 36: ...24 IBM FlashSystem Installing the IBM FlashSystem 810...
Страница 37: ......
Страница 38: ...Part Number 00DH781 Printed in USA GI11 9894 04 1P P N 00DH781...