2
IBM xSeries 350: Installation Guide
Specifications and features
The following table provides a summary of the features and specifications for your
xSeries 350.
Table 1. Features and Specifications.
Microprocessor:
•
Intel
®
Pentium
®
III Xeon™
•
32 KB level-1 cache
•
1 MB level-2 cache (min.)
•
100 MHz front-side bus (FSB)
•
Support for up to four
microprocessors
Memory
:
•
Maximum: 16 GB
•
Type: ECC, SDRAM, registered
DIMMs
•
Slots: 4-way interleaved, 16 slots
Drives standard:
•
Diskette: 1.44 MB
•
CD-ROM: 40X IDE
Expansion bays
:
Slim-high hot-swap
•
Standard: Three
•
Optional: Three
Active PCI expansion slots:
•
One 33 MHz/32-bit
•
Three 66 MHz/64-bit
•
Two 33 MHz/64-bit
Hot-swap power supplies:
270 W (115-230 V ac)
•
Minimum: One
•
Maximum: Three
Redundant cooling:
Six hot-swap fans
Size (4 U)
•
Height: 178 mm (7 in.)
•
Depth: 711.2 mm (28 in.)
•
Width: 482.6 mm (19 in.)
•
Weight: 34.9 kg (77 lb) to 50.4 kg
(111 lb) depending upon
configuration
Integrated functions:
•
Advanced System Management
processor with Light Path
Diagnostics
™
•
Dual-channel Ultra160 SCSI
controller non-RAID (one
internal and one external
channel)
•
One 10BASE-T/100BASE-TX
AMD Ethernet controller
•
Two serial ports
•
One parallel port
•
Two Universal Serial Bus ports
•
Keyboard port
•
Mouse port
•
Video port
Acoustical noise emissions:
•
Sound power, idling: 6.3 bel
maximum
•
Sound power, operating: 6.3 bel
maximum
•
Sound pressure, operating: 47
dBa maximum
Video:
•
S3 video controller
•
Compatible with SVGA and VGA
•
8 MB video memory
Environment:
•
Air temperature:
— Server on: 10
°
to 35
°
C (50
°
to
95
°
F). Altitude: 0 to 914 m
(3000 ft)
— Server on: 10
°
to 32
°
C (50
°
to
89.6
°
F). Altitude: 914 m
(3000 ft.) to 2133 m (7000 ft)
— Server off: 10
°
to 43
°
C (50
°
to
110
°
F). Maximum altitude:
2133 m (7000 ft)
•
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
•
Minimum configuration: 461 Btu
(0.14 kilowatts)
•
Maximum configuration: 1796
Btu (0.53 kilowatts)
Electrical input:
•
Sine-wave input (50-60 Hz)
required
•
Input voltage low range:
— Minimum: 90 V ac
— Maximum: 137 V ac
•
Input voltage high range:
— Minimum: 180 V ac
— Maximum: 265 V ac
•
Input kilovolt-amperes (kVA)
approximately:
— Minimum: 0.08 kVA
— Maximum: 0.52 kVA
Содержание eserver xSeries 350
Страница 3: ...IBM IBM xSeries 350 Installation Guide SC21 P902 50...
Страница 6: ...iv IBM xSeries 350 Installation Guide...
Страница 28: ...16 IBM xSeries 350 Installation Guide...
Страница 32: ...20 IBM xSeries 350 Installation Guide...
Страница 42: ...30 IBM xSeries 350 Installation Guide...
Страница 58: ...46 IBM xSeries 350 Installation Guide...
Страница 60: ...48 IBM xSeries 350 Installation Guide...
Страница 61: ......
Страница 62: ...IBM Part Number 21P9025 Printed in the United States of America 21P9 25...