Note: If you use the Format and Certify option, there may be some blocks
which get placed into the grown defect MAP.
3. If there are bad blocks in the defect MAP, record the information presented and
ensure that this information is kept with the drive. This data is used later when
the drive is to be overwritten.
4. Use the drive as you would normally.
5. When the drive is no longer needed and is to be erased, run the same version of
the Erase Disk selection that was used in step 2.
Note: Using the same version of the service aid is only critical if any bad blocks
were found in step 3.
6. Compare the bad blocks that were recorded with the drive in step 3 with those
that now appear in the grown defect MAP.
Note: If there are differences between the saved data and the newly obtained
data, then all sectors on this drive cannot be overwritten. The new bad
blocks are not overwritten.
7. If the bad block list is the same, continue running the service aid to overwrite the
disk with the chosen pattern(s).
This task can be run directly from the AIX command line. The command syntax is as
follows:
diag -c -d
deviceName
-T "format [-s* fmtcert | erase -a {read | write}] [-F]"
Flag
Description
fmtcert Formats and certifies the disk.
*
Available in no-console mode only.
-F
Force the disk erasure even if all blocks cannot be erased due to errors
accessing a large defect map.
Note: The Erase Disk option in command line mode uses default values. To selectively
read or write, use the diag command in console mode.
Hardfile Attached to PCI SCSI RAID Adapter
This function formats the physical disks attached to a PCI SCSI RAID adapter. This
task can be run directly from the AIX command line. The command syntax is as follows:
diag -c -d
RAID adapterName
-T "format {-l
chId
| -A }"
Flag
Description
-l
Physical disk channel/ID. (An example of a physical disk channel/ID is 27,
where the channel is 2 and the ID is 7.)
-A
All disks
Chapter 6. Introducing Tasks and Service Aids
103
Содержание Eserver pSeries 670
Страница 1: ...pSeries 670 User s Guide SA38 0614 00 ERserver IBM...
Страница 2: ......
Страница 3: ...pSeries 670 User s Guide SA38 0614 00 ERserver IBM...
Страница 14: ...xii Eserver pSeries 670 User s Guide...
Страница 22: ...6 Eserver pSeries 670 User s Guide...
Страница 28: ...12 Eserver pSeries 670 User s Guide...
Страница 88: ...72 Eserver pSeries 670 User s Guide...
Страница 136: ...120 Eserver pSeries 670 User s Guide...
Страница 150: ...134 Eserver pSeries 670 User s Guide...
Страница 154: ...138 Eserver pSeries 670 User s Guide...
Страница 158: ...142 Eserver pSeries 670 User s Guide...
Страница 188: ...172 Eserver pSeries 670 User s Guide...
Страница 194: ...178 Eserver pSeries 670 User s Guide...
Страница 197: ......