Identifying the Terminal Type to the Diagnostics
Note: This is not the same as selecting a console display.
When you run diagnostics, you must identify what type of terminal you are using. If the
terminal type is not known when the FUNCTION SELECTION menu is displayed, the
diagnostics do not allow you to continue until a terminal is selected from the DEFINE
TERMINAL option menu. Select lft for graphical displays.
Undefined Terminal Types
If you specify an undefined terminal type from the DEFINE TERMINAL option menu, the
menu prompts the user to enter a valid terminal type. The menu is redisplays until
either a valid type is entered or you exit the DEFINE TERMINAL option.
Resetting the Terminal
If you enter a terminal type that is valid (according to the DEFINE TERMINAL option
menu) but is not the correct type for the ASCII terminal being used, you may be unable
to read the screen, use the function keys, or use the Enter key. These difficulties can be
bypassed by pressing Ctrl-C to reset the terminal. The screen display which results
from this reset depends on the mode in which the system is being run:
v
Online Normal or Maintenance Mode - The command prompt appears.
v
Standalone Mode or Online Service Mode -The terminal type is reset to
dumb
, the
Diagnostic Operating Instruction panel displays, and you are required to go through
the DEFINE TERMINAL process again.
Running Standalone Diagnostics
Consider the following when you run Standalone Diagnostics:
v
The diagnostic CD must remain in the CD-ROM drive for the entire time that
diagnostics are running.
v
The diagnostic CD-ROM cannot be ejected from the CD-ROM drive once the
diagnostics have loaded. The CD can only be ejected after the system has been
turned off and then turned on (standalone mode) or after the diagnostics program
has terminated (online concurrent mode).
v
The CD-ROM drive from which diagnostics were loaded cannot be tested.
v
The SCSI adapter (or circuitry) controlling the CD-ROM drive from which diagnostics
were loaded cannot be tested.
108
S80 and S85 User’s Guide
Содержание Enterprise Server S80
Страница 1: ...Enterprise Server S80 pSeries 680 Model S85 User s Guide SA38 0557 01 IBM...
Страница 10: ...x S80 and S85 User s Guide...
Страница 14: ...xiv S80 and S85 User s Guide...
Страница 16: ...xvi S80 and S85 User s Guide...
Страница 21: ...Chapter 1 System Introduction 3...
Страница 26: ...8 S80 and S85 User s Guide...
Страница 124: ...106 S80 and S85 User s Guide...
Страница 158: ...I O Drawer 3 Locations 140 S80 and S85 User s Guide...
Страница 194: ...176 S80 and S85 User s Guide...
Страница 214: ...196 S80 and S85 User s Guide...
Страница 216: ...198 S80 and S85 User s Guide...
Страница 218: ...200 S80 and S85 User s Guide...
Страница 220: ...202 S80 and S85 User s Guide...
Страница 228: ...210 S80 and S85 User s Guide...
Страница 232: ...214 S80 and S85 User s Guide...
Страница 236: ...218 S80 and S85 User s Guide...
Страница 263: ...error Handle unexpected modem responses expect 8 r or 7 r or 4 r or 3 r delay 2 done Appendix G Modem Configurations 245...
Страница 264: ...246 S80 and S85 User s Guide...
Страница 274: ...256 S80 and S85 User s Guide...
Страница 281: ......