Replacing
a
hot-swap
fan
The
server
comes
with
a
maximum
of
seven
hot-swap
fans.
If
the
server
has
one
microprocessor,
it
has
six
fans.
If
you
install
a
second
microprocessor,
the
seventh
fan,
fan
4,
comes
with
the
optional
second
microprocessor.
Attention:
To
ensure
proper
server
operation,
if
a
fan
fails,
replace
it
as
soon
as
possible.
The
following
illustration
shows
the
locations
of
the
hot-swap
fans.
Fan 4 (optional)
Fan 5
Fan 6
Fan 7
Fan 1
Fan 2
Fan 3
Fan door A
Fan door B
Complete
the
following
steps
to
replace
a
hot-swap-fan:
1.
Read
the
safety
information
beginning
on
page
v
and
2.
Open
the
fan
door
for
the
failing
fan.
The
LED
near
the
connector
of
the
failing
fan
assembly
is
lit.
Attention:
To
ensure
proper
system
cooling,
do
not
leave
the
fan
doors
open
for
more
than
30
minutes
during
this
procedure.
3.
Disconnect
the
cable
of
the
failing
fan
from
the
connector.
4.
Pull
up
on
the
orange
tab
on
the
side
of
the
failing
fan;
then,
lift
the
fan
out
of
the
server.
5.
Orient
the
new
fan
in
the
same
position
as
the
fan
you
removed.
Make
sure
that
the
airflow
indicator,
on
top
of
the
fan,
is
pointing
to
the
rear
of
the
server.
6.
Push
the
fan
assembly
down
into
the
server
until
the
blue
grommets
are
correctly
seated.
7.
Connect
the
fan
cable
to
the
fan
connector.
8.
Close
the
fan
door.
9.
Go
to
Chapter
2.
Installing
options
41
Содержание E Server x336 Series
Страница 1: ...IBM xSeries 336 Type 8837 Option Installation Guide ERserver...
Страница 2: ......
Страница 3: ...IBM xSeries 336 Type 8837 Option Installation Guide ERserver...
Страница 62: ...50 IBM xSeries 336 Type 8837 Option Installation Guide...
Страница 70: ...58 IBM xSeries 336 Type 8837 Option Installation Guide...
Страница 74: ...62 IBM xSeries 336 Type 8837 Option Installation Guide...
Страница 75: ......
Страница 76: ...Part Number 25K9151 Printed in USA 1P P N 25K9151...