background image

Note:

  

To

 

make

 

sure

 

there

 

is

 

adequate

 

system

 

cooling,

 

do

 

not

 

operate

 

the

 

server

 

for

 

more

 

than

 

2

 

minutes

 

without

 

either

 

a

 

hard

 

disk

 

drive

 

or

 

a

 

filler

 

panel

 

installed

 

in

 

each

 

bay.

 

3.

   

Insert

 

the

 

simple

 

swap

 

hard

 

disk

 

drive

 

into

 

the

 

drive

 

tray

 

assembly.

 

4.

   

Slide

 

the

 

drive

 

into

 

the

 

bay

 

until

 

the

 

rear

 

of

 

the

 

drive

 

snaps

 

into

 

place

 

with

 

the

 

rear

 

panel-mount

 

connector.

 

This

 

simple

 

swap

 

connector

 

contains

 

the

 

signal

 

and

 

power

 

connections

 

that

 

are

 

needed

 

by

 

the

 

SATA

 

drive.

 

5.

   

Install

 

the

 

filler

 

panel

 

for

 

the

 

drive.

 

6.

   

If

 

you

 

have

 

other

 

options

 

to

 

install

 

or

 

remove,

 

do

 

so

 

now.

 

7.

   

Go

 

to

 

“Completing

 

the

 

installation”

 

on

 

page

 

44.

Removing

 

and

 

installing

 

an

 

internal

 

DVD-ROM

 

drive

 

or

 

DVD-ROM

 

blank

 

bezel

 

The

 

following

 

notes

 

describe

 

the

 

type

 

of

 

DVD-ROM

 

drive

 

the

 

server

 

supports

 

and

 

other

 

information

 

that

 

you

 

must

 

consider

 

when

 

installing

 

a

 

DVD-ROM

 

drive:

 

v

   

The

 

server

 

supports

 

the

 

installation

 

of

 

an

 

optional

 

DVD-ROM

 

drive

 

only

 

when

 

you

 

are

 

using

 

a

 

3.5-inch

 

hard

 

disk

 

drive

 

configuration.

 

v

   

The

 

DVD-ROM

 

drive

 

must

 

be

 

a

 

slim

 

9.5

 

mm

 

drive

 

and

 

you

 

install

 

it

 

underneath

 

the

 

3.5-inch

 

hard

 

disk

 

drive,

 

on

 

the

 

left

 

side.

 

Note:

  

DVD-ROM,

 

CD-ROM,

 

and

 

diskette

 

drives

 

can

 

also

 

be

 

attached

 

externally

 

using

 

the

 

USB

 

connector.

If

 

you

 

are

 

removing

 

an

 

internal

 

DVD-ROM

 

drive

 

or

 

blank

 

bezel,

 

continue

 

with

 

“Removing

 

an

 

internal

 

DVD-ROM

 

drive

 

or

 

DVD-ROM

 

blank

 

bezel”

 

on

 

page

 

27.

 

If

 

you

 

are

 

installing

 

an

 

internal

 

DVD-ROM

 

drive

 

or

 

blank

 

bezel,

 

go

 

to

 

“Installing

 

an

 

internal

 

DVD-ROM

 

drive

 

or

 

DVD-ROM

 

blank

 

bezel”

 

on

 

page

 

29.

 

Removing

 

an

 

internal

 

DVD-ROM

 

drive

 

or

 

DVD-ROM

 

blank

 

bezel

 

Complete

 

the

 

following

 

steps

 

to

 

remove

 

an

 

internal

 

DVD-ROM

 

drive

 

or

 

DVD-ROM

 

blank

 

bezel:

 

1.

   

Read

 

the

 

safety

 

information

 

beginning

 

on

 

page

 

v

 

and

 

“Installation

 

guidelines”

 

on

 

page

 

13.

 

2.

   

Turn

 

off

 

the

 

server

 

and

 

peripheral

 

devices

 

and

 

disconnect

 

all

 

power

 

cords

 

and

 

external

 

cables

 

(see

 

“Turning

 

off

 

the

 

server”

 

on

 

page

 

15);

 

then,

 

remove

 

the

 

cover

 

(see

 

“Removing

 

the

 

server

 

cover”

 

on

 

page

 

17).

   

Chapter

 

2.

 

Installing

 

options

 

27

Содержание E Server x336 Series

Страница 1: ...IBM xSeries 336 Type 8837 Option Installation Guide ERserver...

Страница 2: ......

Страница 3: ...IBM xSeries 336 Type 8837 Option Installation Guide ERserver...

Страница 4: ...he general information in Notices on page 51 First Edition July 2004 Copyright International Business Machines Corporation 2004 All rights reserved US Government Users Restricted Rights Use duplicatio...

Страница 5: ...lleert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation...

Страница 6: ...ersions of the caution or danger statement in theIBM Safety Information book For example if a caution statement begins with a number 1 translations for that caution statement appear in the IBM Safety...

Страница 7: ...equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instru...

Страница 8: ...ement 3 CAUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following v Do not remove the covers Removing the covers of the laser product...

Страница 9: ...pply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are...

Страница 10: ...accessories sold with this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling ADVERTENC...

Страница 11: ...talling the Remote Supervisor Adapter II SlimLine 22 Installing a hard disk drive 24 Installing a hot swap hard disk drive 25 Installing a simple swap hard disk drive 26 Removing and installing an int...

Страница 12: ...ada Class A emission compliance statement 54 Australia and New Zealand Class A statement 54 United Kingdom telecommunications safety requirement 54 European Union EMC Directive conformance statement 5...

Страница 13: ...tion document v Rack Installation Instructions This printed document contains instructions for installing the server in a rack v Hardware Maintenance Manual and Troubleshooting Guide This document is...

Страница 14: ...lethal or extremely hazardous to you A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation Major components of the xSerie...

Страница 15: ...mote Supervisor Adapter II SlimLine assembly optional Heat sink Heat sink retainer Microprocessor VRM System board Power supply Cover Filler panel DVD ROM drive SCSI hard drive Fan 4 optional Fan 5 Fa...

Страница 16: ...connectors on the system board Front operator panel J2 SATA 0 connector J36 SATA 1 connector J31 Fan 1 3 connector J30 Fan 4 7 connector J33 Front USB connector J38 System board connector SCSI connec...

Страница 17: ...ers turn off the server then disconnect all power cords and external cables Review the information in Safety on page iii Installation guidelines on page 13 Handling static sensitive devices on page 14...

Страница 18: ...ation shows the external input output connectors on the system board Remote Supervisor Adapter II SlimLine Ethernet J9 Dual Ethernet J11 Mouse J16 Keyboard 17 USB 1 J18 USB 2 J19 Serial J29 Video J37...

Страница 19: ...IMM 4 10 error LED CR DIMM 5 11 error LED CR DIMM 6 12 error LED CR DIMM 7 13 error LED CR DIMM 8 15 error LED CR VRM 2 error LED CR26 VRM 1 error LED CR3 System board fault LED CR4 Ethernet 1 activit...

Страница 20: ...U16 Microprocessor 2 U32 VRM 2 J25 DVD connector J39 Remote Supervisor Adapter II SlimLine J41 Slot 2 PCI X 64 bit 133 MHz or PCI Express x8 U34 Slot 1 PCI X slot 1 64 bit 100 MHz U33 Battery BH1 VRM...

Страница 21: ...shows the cable channels on the system board where you should route the cables from user installable options Hard disk drive cable routing System cable routing Low profile PCI cable routing Full leng...

Страница 22: ...error log v If a Remote Supervisor Adapter II SlimLine option is not installed in the server use the POST error log Note The Intelligent Platform Management Interface IPMI baseboard management contro...

Страница 23: ...the LED flashes an invalid DIMM configuration has occurred Replace the failing DIMM which is indicated by the lit LED on the system board If a configuration error has occurred make sure the DIMMs are...

Страница 24: ...ion PCI B An error has occurred on PCI bus B Check the following items for errors v PCI PCI X Adapter in Slots 1 or 2 v On board SCSI v The system board might have a malfunction PCI C An error has occ...

Страница 25: ...onents See the instructions for removing or installing a specific hot swap component for any additional procedures that you might have to perform before you remove or install the component v For a lis...

Страница 26: ...atic protective packages until you are ready to install them To reduce the possibility of damage from electrostatic discharge observe the following precautions v Limit your movement Movement can cause...

Страница 27: ...Wake on LAN feature the Wake on LAN feature can turn on the server Turning off the server When you turn off the server and leave it connected to ac power the power supply fans continue to run and the...

Страница 28: ...If you installed the Remote Supervisor Adapter II SlimLine option in the server the server can be turned off from the Remote Supervisor Adapter II user interface v If the Wake on LAN feature turned on...

Страница 29: ...door panel up To open fan door B slide the two slide latches to the right and lift the door panel up 4 Remove the server cover a Lift up the cover release latch and slide the cover to the rear of the...

Страница 30: ...ed Ethernet controllers Integrated SCSI controller PCI X slot 1 PCI X or PCI Express slot 2 Complete the following steps to install an adapter 1 Read the safety information beginning on page v and Ins...

Страница 31: ...u turn on the server An improperly seated adapter might cause damage to the system board the riser card or the adapter 5 As you start inserting the adapter through the slot 1 opening align the edge co...

Страница 32: ...retention latches Riser card Riser card retention latches Slot 2 adapter cover Access hole to retention latch 3 Lift up and remove the slot 2 adapter cover The slot 2 riser card is attached to the ad...

Страница 33: ...Make sure that the adapter snaps into place and is securely in the riser card connector Attention When you install an adapter make sure that you seat the adapter correctly in the riser card connector...

Страница 34: ...age 9 for cable routing information 13 If you have other options to install or remove do so now 14 Go to Completing the installation on page 44 Installing the Remote Supervisor Adapter II SlimLine The...

Страница 35: ...ne assembly 4 The server comes with mounting brackets on the system board There are front and rear mounting brackets that hold the Remote Supervisor Adapter II SlimLine in place Align the locating pin...

Страница 36: ...Each hot swap drive has a single connector attached SCA connector which connects directly to the hot swap SCSI backplane The backplane attaches to connector J 35 on the system board and controls the S...

Страница 37: ...safety information beginning on page v and Installation guidelines on page 13 2 Remove the filler panel from the drive bay Note To make sure there is adequate system cooling do not operate the server...

Страница 38: ...tivity LED to verify that the drive is operating correctly 6 If you have other options to install or remove do so now 7 Go to Completing the installation on page 44 Installing a simple swap hard disk...

Страница 39: ...ion of an optional DVD ROM drive only when you are using a 3 5 inch hard disk drive configuration v The DVD ROM drive must be a slim 9 5 mm drive and you install it underneath the 3 5 inch hard disk d...

Страница 40: ...VD ROM drive DVD ROM drive retention clip DVD ROM drive release latch Release latch 5 Press the release latch on the left side of the DVD ROM drive or DVD ROM blank bezel then pull the drive or blank...

Страница 41: ...ning on page v and Installation guidelines on page 13 2 Turn off the server and peripheral devices and disconnect all power cords and external cables see Turning off the server on page 15 then remove...

Страница 42: ...ard disk drive from the 3 5 inch hard drive cage reinstall it See Installing a hard disk drive on page 24 for instructions 7 Place the 3 5 inch hard drive cage in the server then rotate the two releas...

Страница 43: ...ard The server comes with a minimum of 512 MB two 256 MB DIMMs v You can increase the amount of memory in the server by replacing them with higher capacity DIMMs or by installing an additional pair of...

Страница 44: ...memory sparing DIMM pair must be the same speed type and the same size as or larger than the active DIMM pair To enable memory mirroring or sparing through the Configuration Setup Utility program sel...

Страница 45: ...ctor by applying pressure on both ends of the DIMM simultaneously The retaining clips snap into the locked position when the DIMM is firmly seated in the connector If there is a gap between the DIMM a...

Страница 46: ...w microprocessor comes in a kit with a VRM a cooling fan and a heat sink 3 To use SMP obtain an SMP capable operating system optional For a list of supported operating systems go to http www ibm com p...

Страница 47: ...n b Rotate the locking lever on the microprocessor socket from its closed and locked position until it stops or clicks in the fully open position approximately 135 angle Note The microprocessor releas...

Страница 48: ...g so can damage the microprocessor pins Loosen one captive screw fully before loosening the other captive screw to help break the bond between the components without damaging them 7 Remove the heat si...

Страница 49: ...nt of the second microprocessor See Replacing a hot swap fan on page 41 for instructions 9 If you have other options to install or remove do so now 10 Go to Completing the installation on page 44 Chap...

Страница 50: ...ailure the redundant power supply continues to power the system Two power supplies are supported per server v See Using Y power cord connectors for power backup on page 40 for information on how to pr...

Страница 51: ...ct the power cord to a properly grounded electrical outlet 6 Make sure that the power supply fan starts and the ac power LED top and dc power LED bottom on the power supply are lit indicating that the...

Страница 52: ...e connected correctly to ensure optimum power backup to the servers Connect the Y power cord to two power supplies in two different servers then connect the other end of the Y power cord to a Back UPS...

Страница 53: ...guidelines on page 13 2 Open the fan door for the failing fan The LED near the connector of the failing fan assembly is lit Attention To ensure proper system cooling do not leave the fan doors open fo...

Страница 54: ...marketing representative Note After you replace the battery you must reconfigure the server and reset the system date and time Statement 2 CAUTION When replacing the lithium battery use only IBM Part...

Страница 55: ...that the plus side of the battery is facing toward the center of the server toward slots 1 and 2 b Pull the retainer tab out of the way so that you can slide the battery into its socket c Slide the b...

Страница 56: ...ey do not interfere with the cover installation See System board cable channels on page 9 for information about cable routing Important Before sliding the cover forward make sure that all the tabs on...

Страница 57: ...LEDs Power Location System error Video Serial USBs Mouse Keyboard Ethernet LEDs Ethernet LEDs Dual GB Ethernet Remote Supervisor Adapter II Ethernet SlimLine Remote Supervisor Adapter II SlimLine Eth...

Страница 58: ...d you have installed or removed a hard disk drive see the documentation that comes with the RAID adapter for information about reconfiguring the disk arrays If you have installed the Remote Supervisor...

Страница 59: ...Keyboard Ethernet LEDs Dual GB Ethernet Remote Supervisor Adapter II SlimLine Ethernet Front view The following illustration shows the location of the USB connector on the front of the server Model S...

Страница 60: ...6 Type 8837 User s Guide on the IBM xSeries Documentation CD for more information about the Ethernet controllers 2 The third Ethernet connector is a dedicated connector that is active only when you in...

Страница 61: ...ration shows a USB connector 1 4 Use a 4 pin cable to connect a device to a USB connector If you need to connect more USB devices than the server has USB connectors for use a USB hub to connect additi...

Страница 62: ...50 IBM xSeries 336 Type 8837 Option Installation Guide...

Страница 63: ...Y OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer...

Страница 64: ...ther countries or both UNIX is a registered trademark of The Open Group in the United States and other countries Java and all Java based trademarks and logos are trademarks or registered trademarks of...

Страница 65: ...include user manuals or all program functionality Product recycling and disposal This unit contains materials such as circuit boards cables electromagnetic compatibility gaskets and connectors which...

Страница 66: ...r by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC...

Страница 67: ...has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class A equipment were derived for comm...

Страница 68: ...art number Used in these countries and regions 02K0546 China 13F9940 Australia Fiji Kiribati Nauru New Zealand Papua New Guinea 13F9979 Afghanistan Albania Algeria Andorra Angola Armenia Austria Azerb...

Страница 69: ...s Barbados Belize Bermuda Bolivia Brazil Caicos Islands Canada Cayman Islands Costa Rica Colombia Cuba Dominican Republic Ecuador El Salvador Guam Guatemala Haiti Honduras Jamaica Japan Mexico Microne...

Страница 70: ...58 IBM xSeries 336 Type 8837 Option Installation Guide...

Страница 71: ...g 27 29 removing 27 DVD ROM drive installing 27 29 removing 27 E electronic emission Class A notice 54 Ethernet port 48 external cabling 45 F fan doors 41 fan replacing 41 FCC Class A notice 54 front...

Страница 72: ...t 48 port continued pointing device 48 power power on LED 15 power cord Y connectors 40 power cords 56 R related documentation 1 related publications 1 reliability guidelines 13 remove server cover 17...

Страница 73: ...notice 54 United States FCC Class A notice 54 Universal Serial Bus connector 49 updating server configuration 45 USB connector 49 V video connector 49 W Wake on LAN feature 15 16 web site IBM support...

Страница 74: ...62 IBM xSeries 336 Type 8837 Option Installation Guide...

Страница 75: ......

Страница 76: ...Part Number 25K9151 Printed in USA 1P P N 25K9151...

Отзывы: