Check the entry for the database in IBM Cognos Configuration or the [PowerPlay
Server List] section of the .ini file. It must match the database definition specified
in IBM Cognos Impromptu when the .iqd file was created.
TR2729
Measure measure_name has a time state rollup specified. This measure does not
touch the lowest level in dimension dimension_name causing time state rollup
values to be zero in any cubes that reference this measure.
The column providing date values for the time dimension does not contain enough
detail to allow calculation of the time-state rollups for the measures in the model.
For example, you define a time-state measure called Inventory Level and your time
dimension contains Year, Month, and Week. However, you discover that the dates
in your source files do not provide details down to the Week level in the time
dimension.
Procedure
When defining time-state measures, ensure that the column providing date values
for your model is sufficiently detailed to calculate the specified time-state rollups.
If necessary, open the property sheet for the column associated with your time
dimension and reset the
Degree of detail
property on the
Time
tab.
TR2731
Cube group cube_group_name is not defined in the primary drill-down path in
dimension dimension_name. A cube group must be specified in the primary drill
down of a dimension that has alternate drill downs.
You have tried to define cube groups based on a target level that exists in an
alternate drill-down path. Cube groups can exist only for levels in the primary
drill-down path.
Procedure
To resolve the problem, first ensure that the current primary drill-down path does
not contain features such as allocated measures or partitioning that are not allowed
in alternate drill-down paths. Then, on the
General
tab of the appropriate
Drill
Category
property sheet, make the drill-down path, in which you define the cube
group, the primary drill-down path. Then convert the path that was originally the
primary path to an alternative drill-down path, if required.
TR2732
The target category category_name in cube group cube_group_name which
summarizes external categories cannot be suppressed or cloaked in any dimension
views in dimension dimension_name.
In defining a cube group, you have tried to omit one of the categories in the target
level by applying a dimension view that uses
Suppress
or
Cloak
.
Appendix C. IBM Cognos Transformer Error Messages
307
Содержание Cognos
Страница 1: ...IBM Cognos Transformer Version 10 1 1 User Guide ...
Страница 106: ...92 IBM Cognos Transformer Version 10 1 1 User Guide ...
Страница 136: ...122 IBM Cognos Transformer Version 10 1 1 User Guide ...
Страница 160: ...146 IBM Cognos Transformer Version 10 1 1 User Guide ...
Страница 174: ...160 IBM Cognos Transformer Version 10 1 1 User Guide ...
Страница 326: ...312 IBM Cognos Transformer Version 10 1 1 User Guide ...
Страница 352: ...338 IBM Cognos Transformer Version 10 1 1 User Guide ...
Страница 394: ...380 IBM Cognos Transformer Version 10 1 1 User Guide ...
Страница 398: ...384 IBM Cognos Transformer Version 10 1 1 User Guide ...
Страница 411: ...Y year function 362 years between function 362 Index 397 ...