Table 25. Definition of status light combinations (continued)
Ready
Ready
(green)
Activity
Activity
(green)
Fault
Fault
(amber)
Definition
Off or On
Off or Flashing
On
The tape drive requires cleaning. See
Cleaning the tape drive.
v
If the Ready light is on, a tape cartridge is
in the drive. If the light is off, a cartridge is
not in the drive.
v
If the Activity light flashes, a tape cartridge
is in the drive and tape movement is
occurring. If the light is off, no tape
movement is occurring.
Off
Off
Off or On
One of the following conditions exists:
v
The power is off (Fault light is off).
v
The POST completed successfully, but no
tape cartridge has been inserted.
v
If the Fault light is on, cleaning is required.
See Cleaning the tape drive.
On
Off or Flashing
Off or On
A data cartridge has been inserted.
v
The device is ready to receive commands
from the system (whether the Fault light is
on or off).
v
If the Fault light is on, cleaning is required.
See Cleaning the tape drive.
v
If the Activity light flashes, a tape cartridge
is in the drive and tape movement is
occurring. If the light is off, no tape
movement is occurring.
On
Flashing
Off or On
The tape is in motion, and the device is
running an operation or is cleaning.
Off
Off
Flashing
The device detected an internal fault that
requires corrective action.
1.
Reset the error by turning the power off
to the device, then turning it back on, or
by holding down the Unload/Reset
button for 8 seconds.
2.
If the Fault light still flashes after the
reset, contact your service provider.
Notes:
v
The device needs cleaning when the tape drive turns on the Fault status light (solid amber). The light
turns on when the device exceeds a preset operating limit.
v
The recommended preventive-maintenance cleaning frequency is approximately 50 tape motion hours.
Tape motion hours are defined as the time that the tape drive is moving tape.
v
When the Fault light turns on (solid amber), the device causes AIX to log an information error
(TAPE_ERR6) in the AIX log, indicating that the tape drive needs to be cleaned.
v
Use only quality media and cleaning cartridges.
v
The device is designed to operate in typical office environments. Dirty environments or other poor
environments might damage the tape drive. It is the customer’s responsibility to provide the proper
operating environment.
Chapter 2. Managing tape drives
53
Содержание Bull Escala E5-700
Страница 1: ...Managing Devices for the M6 700 or M7 700 ESCALA Power7 REFERENCE 86 A1 84FF 00...
Страница 2: ......
Страница 14: ...2 Power Systems Managing devices...
Страница 84: ...72 Power Systems Managing devices...
Страница 86: ...74 Power Systems Managing devices...
Страница 88: ...76 Power Systems Managing devices...