Table 12. Definition of Status Light Combinations (continued)
Operation
Ready
Activity
Cleaning
Fault
1
All 4 LEDs will be on solid for 2 seconds.
2
If the drive completes Power-On Self-Test (POST) within 2 seconds, no POST in progress indication is required.
3
A solid amber Clean LED indicates that the drive needs cleaning. In most cases the drive will continue to function,
but it should be cleaned as soon as possible.
4
If the cleaning function completes and the solid amber Clean LED remains lit, the cleaning function was not
successful. The cleaning cartridge may be depleted. Obtain a new LTO cleaning cartridge and use it to perform the
cleaning function again.
5
The Fault LED will flash to indicate an unrecoverable error. An unrecoverable error is an error condition that
results in the drive not being able to function unless initiator, operator, or service intervention is applied. An
unrecoverable drive failure is usually the result of a hardware error condition. One of the following actions will be
needed to clear the flashing Fault LED:
v
Hard SCSI reset
v
Cartridge eject
v
Power cycle
v
Retry microcode download
An unrecoverable cartridge (media) failure is usually the result of a defective cartridge, media, or cartridge state
and will require the drive to eject the cartridge (if possible) to clear the flashing LED.
6
The firmware download failed and the drive is not functional. The drive boot code is in control and the firmware
download must be retried.
7
When the Fault LED is solid, it indicates an over temperature condition. The drive has exceeded its preset
temperature limit, and if a tape is present in the drive it will be ejected. The Fault LED will remain solid until the
drive temperature drops below a secondary temperature limit, and a data or cleaning cartridge is inserted.
8
While running drive diagnostics (using either SEND DIAG or the Self-Test Procedure), a media-related problem
(hard media error or excessive soft error rate) will be reported as a media failure (with flashing Clean LED), and a
write-protected, damaged, or incompatible cartridge will be reported as incorrect media (with Activity and Clean
LEDs flashing simultaneously).
Tape cartridges (FC 5755)
Learn about the types of tape cartridges that are available for this drive.
Available tape cartridges
Table 13. LTO Ultrium data cartridges
Part Number
Type of Cartridge
Length
08L9120
100/200GB LTO Ultrium 1 Data
Cartridges
610 m (2000 ft )
08L9870
200/400GB LTO Ultrium 2 Data
Cartridges
610 m (2000 ft )
24R0395
LTO Gen-2 Test Tape
610 m (2000 ft )
35L2086
Universal Cleaning Tape
– –
Chapter 2. Managing tape drives
25
Содержание Bull Escala E5-700
Страница 1: ...Managing Devices for the M6 700 or M7 700 ESCALA Power7 REFERENCE 86 A1 84FF 00...
Страница 2: ......
Страница 14: ...2 Power Systems Managing devices...
Страница 84: ...72 Power Systems Managing devices...
Страница 86: ...74 Power Systems Managing devices...
Страница 88: ...76 Power Systems Managing devices...