8.
To select a different tty port, use the cursor keys to either increment or decrement the port number.
9.
Once a tty port is selected, then select one of the following items:
a.
Wrap data by typing a
T
. If this option is chosen, use wrap plug part number 43G0928. Insert the
wrap plug into the tty port.
b.
Monitor the data on the selected port by typing a
D
.
10.
To exit the diagnostic program, press ESC.
General purpose diagnostic procedures, visual inspections
Ethernet cables
v
Ensure an Ethernet cable is attached to the 7036-P16 and the host server.
v
Ensure the Ethernet cable is wired correctly.
v
Ensure the Ethernet cable is good.
Serial cables
v
Ensure a serial cable is attached to every 7036-P16 port that is in use.
v
Ensure the serial cables are wired correctly.
v
Ensure the serial cables are good.
Investigating Ethernet network problems associated with the 7036-P16
1.
Gather the following information:
For the 7036-P16:
v
MAC Address: [MAC Address] (MAC Address label is on the back of the 7036-P16)
v
IP Address: [7036-P16 IP Address]
v
Default Gateway: [IP Gateway Address]
v
Name Server: [Name Server Address]
v
Host Name: [Host Name] (if a host name is assigned)
For the host server:
v
Machine Type and Model
v
AIX Level
v
IP Address: [Host server IP Address]
v
Default Gateway: [IP Gateway Address]
v
Name Server: [Name Server Address]
v
Host Name: [Host Name] (if a host name is assigned)
2.
Ping the 7036-P16 from the host server by typing:
ping -c 1 [7036-P16 IP Address]
If the 7036-P16 responds to the ping, then both devices are on the network; the problem is not a
network attachment problem. If the ping times out, then either the 7036-P16 or the host server is not
on the network.
3.
Use traceroute to see where the link between the 7036-P16 and the host server is broken. Type:
traceroute [7036-P16 IP Address]
Replacing and reconfiguring the 7036-P16
You might need to create a 7036-P16 configuration file, reconfigure a 7036-P16 from a stored configuration
file, or replace a 7036-P16. Use the procedures in this section to perform this task.
This section provides instructions on how to perform the following tasks:
v
Creating a 7036-P16 configuration file
v
Reconfiguring a 7036-P16 from a stored configuration file
94
Power Systems: Managing devices
Содержание Bull Escala E5-700
Страница 1: ...Managing Devices for the M6 700 or M7 700 ESCALA Power7 REFERENCE 86 A1 84FF 00...
Страница 2: ......
Страница 14: ...2 Power Systems Managing devices...
Страница 84: ...72 Power Systems Managing devices...
Страница 86: ...74 Power Systems Managing devices...
Страница 88: ...76 Power Systems Managing devices...