6.
Use the cursor to select:
cts_16_r
, then press Enter.
7.
Move the cursor to the IP Address box and type:
[IP Address]
, then press Enter. This is the [IP
Address of the target 7036-P16] used in Step 1.
Upon successful completion of this command the user will see the following on the screen:
Command:
OK stdout: yes stderr: no Before command completion, additional instructions may appear.
sa[device number] Available
8.
Press F3.
9.
To configure additional devices, repeat Steps 7. through 10.
10.
Press F10 to exit from
smitty
and return to the server’s command line.
After the serial device is configured, the terminal type (tty) ports may be configured.
Configuring a 7036-P16 system port tty on an AIX host server
Assumptions:
v
The target 7036-P16 and the host server are configured on an Ethernet network.
v
The target 7036-P16 and the host server are attached to an Ethernet network.
v
The Digi RealPort software is installed on the server.
Gather the following information:
v
IP Address of the target 7036-P16: [7036-P16 IP Address]
v
IP Address of the host server: [Host Server IP Address]
v
Root password of target 7036-P16
Procedure:
1.
Ensure that the 7036-P16 and the server are on the network. Ping the 7036-P16 by typing the
following command:
ping -c 1 [IP Address of target 7036-P16]
Note:
If the 7036-P16 responds to the ping, then it is on the network and the user may proceed to
the next step. If the 7036-P16 does not respond to the ping, then the 7036-P16 is not on the network
and the user must perform the network configuration procedure, see “Configuring the 7036-P16 into
the network” on page 90.
2.
Ensure that the Digi RealPort Software is installed on the server. Type the following command:
lslpp
-l | grep digi
Note:
The response indicates that the
digiasync.realport.obj
file is installed. If the response indicates
the Digi RealPort Software is installed then proceed to the next step. If there is no response, then the
Digi RealPort Software is not installed and the user must install the Digi RealPort software, see
“Configuring the 7036-P16 into the network” on page 90.
3.
Type:
smitty tty
, then press Enter.
4.
Use the cursor to select:
Add a tty
, then press Enter.
5.
Use the cursor to select:
tty rs232 Asynchronous Terminal
, then press Enter.
6.
Use the cursor to select:
sa[device number] Available IBM LAN Attached RAN 16
, then press Enter.
7.
Enter a port number not already assigned to a tty, for example 1, and press Enter
Upon successful completion of this command the user sees the following on the screen:
Command: OK
stdout: yes stderr: no Before command completion, additional instructions may appear.
tty[number] Available
Note:
The [number] is the number assigned by
smitty
as the next available tty device.
8.
Press F3.
9.
To configure additional tty devices, repeat Steps 7. through 9.
Chapter 7. Managing communications devices
89
Содержание Bull Escala E5-700
Страница 1: ...Managing Devices for the M6 700 or M7 700 ESCALA Power7 REFERENCE 86 A1 84FF 00...
Страница 2: ......
Страница 14: ...2 Power Systems Managing devices...
Страница 84: ...72 Power Systems Managing devices...
Страница 86: ...74 Power Systems Managing devices...
Страница 88: ...76 Power Systems Managing devices...