![IBM 8874 - eServer xSeries MXE 460 Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/ibm/8874-eserver-xseries-mxe-460/8874-eserver-xseries-mxe-460_installation-manual_4045688092.webp)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Lit
light
path
diagnostics
LED
with
the
system-error
LED
also
lit
Description
Action
RAID
The
RAID
adapter
(ServeRAID-8i)
has
indicated
a
fault.
1.
Check
the
BMC
log
or
the
system-error
log
for
information.
2.
Reseat
the
following
components:
a.
RAID
adapter
b.
Hard
disk
drives
c.
I/O
board
3.
Replace
the
components
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
NONRED
The
server
is
operating
with
nonredundant
power.
If
a
power
supply
or
ac
power
source
fails,
the
system
will
be
over
spec.
Note:
The
LOG
LED
might
also
be
lit.
1.
If
the
PS
LED
on
the
light
path
diagnostics
panel
is
lit,
follow
the
instructions
for
that
LED.
2.
Replace
the
failing
power
supply.
3.
Remove
optional
devices.
4.
Use
220
V
ac
instead
of
110
V
ac.
TEMP
A
system
temperature
or
component
has
exceeded
specifications.
Note:
A
fan
LED
might
also
be
lit.
1.
See
the
BMC
log
or
the
system-error
log
for
the
source
of
the
fault.
2.
Make
sure
that
the
airflow
of
the
server
is
not
blocked.
3.
If
a
fan
LED
is
lit,
reseat
the
fan.
4.
Replace
the
fan
for
which
the
LED
is
lit.
5.
Make
sure
that
the
room
is
neither
too
hot
nor
too
cold
(see
“Environment”
in
“Features
and
specifications”
on
page
4).
6.
If
one
of
the
VRDs
indicates
“hot,”
ac
power
must
be
removed
before
dc
power
can
be
restored.
FAN
A
fan
has
failed
or
has
been
removed.
Note:
A
failing
fan
can
also
cause
the
TEMP
LED
to
be
lit.
1.
Reinstall
the
removed
fan.
2.
If
an
individual
fan
LED
is
lit,
replace
the
fan.
3.
Reseat
the
microprocessor
tray.
4.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
PCI
BRD
The
PCI-X
board
has
failed.
1.
(Trained
service
technician
only)
Reseat
the
PCI-X
board
assembly.
2.
(Trained
service
technician
only)
Replace
the
PCI-X
board
assembly.
CPU
BRD
The
microprocessor
tray
has
failed.
1.
Reseat
the
microprocessor
tray.
2.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
I/O
BRD
The
I/O
board
has
failed.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
80
IBM
ERserver
xSeries
460
Type
8872
and
xSeries
MXE
460
Type
8874:
Installation
Guide
Содержание 8874 - eServer xSeries MXE 460
Страница 3: ...IBM ERserver xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Installation Guide...
Страница 18: ...6 IBM ERserver xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Installation Guide...
Страница 42: ...30 IBM ERserver xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Installation Guide...
Страница 68: ...56 IBM ERserver xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Installation Guide...
Страница 100: ...88 IBM ERserver xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Installation Guide...
Страница 104: ...92 IBM ERserver xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 Installation Guide...
Страница 105: ......
Страница 106: ...Part Number 31R1512 Printed in USA 1P P N 31R1512...