8.
Set
any
jumpers
or
switches
on
the
drive
according
to
the
documentation
that
comes
with
the
drive.
Note:
You
might
find
it
easier
to
install
the
new
drive
from
the
front
and
then
attach
the
cables.
9.
If
you
are
installing
a
3.5-in.
drive
in
bay
2,
attach
the
5.25-in.
conversion
kit,
which
you
can
order
from
IBM,
to
the
3.5-in.
drive.
10.
Remove
the
large
drive
clip
from
the
side
of
the
drive
cage
for
bays
1
through
3.
Slide
the
drive
clip
toward
the
rear
of
the
server;
then,
snap
the
drive
clip
into
the
screw
holes
on
the
side
of
the
drive
or
conversion
kit.
11.
Slide
the
drive
into
the
drive
bay
until
it
snaps
in
place.
12.
Determine
whether
the
drive
is
an
IDE
or
SCSI
device;
then,
connect
one
end
of
the
applicable
signal
cable
into
the
back
of
the
drive
and
make
sure
that
the
other
end
of
this
cable
is
connected
into
the
applicable
IDE
or
SCSI
connector
on
the
system
board.
v
If
you
are
installing
a
SCSI
removable-media
drive,
use
the
one-drop
SCSI
cable
that
comes
with
the
drive
and
connect
it
to
SCSI
channel
A
(SCSI1).
See
“Power
and
signal
cables
for
internal
drives”
on
page
44
for
additional
information
about
cabling
drives
and
“System
board
internal
connectors”
on
page
86
for
the
location
of
IDE
and
SCSI
connectors
on
the
system
board.
v
If
there
are
open
connectors
on
the
cable
connecting
an
existing
IDE
drive,
you
can
use
this
cable
to
connect
the
new
drive.
The
4-connector
SCSI
cable
that
comes
with
non-hot-swap
model
servers
cannot
be
used
to
connect
a
SCSI
drive
in
bay
2.
13.
Route
the
signal
cable
so
that
it
does
not
block
the
airflow
to
the
rear
of
the
drives
or
over
the
microprocessor
and
memory.
14.
If
you
have
another
drive
to
install
or
remove,
do
so
now.
15.
If
you
have
other
options
to
install
or
remove,
do
so
now;
otherwise,
replace
the
support
bracket
(see
“Removing
and
installing
the
support
bracket”
on
page
32),
replace
the
bezel
(see
“Replacing
the
bezel”
on
page
31),
and
then
go
to
“Completing
the
installation”
on
page
60
Installing
a
hot-swap
SCSI
hard
disk
drive
in
bay
4,
5,
6,
7,
8,
or
9
Some
server
models
support
hot-swap
hard
disk
drives.
The
SCSI
ID
for
each
hot-swap
hard
disk
drive
is
printed
on
the
hot-swap
lock
bar.
Before
you
install
a
hot-swap
hard
disk
drive,
read
the
following
information:
v
Inspect
the
drive
tray
for
signs
of
damage.
v
Make
sure
that
the
drive
is
correctly
installed
in
the
tray.
v
To
maintain
proper
system
cooling,
do
not
operate
the
server
for
more
than
10
minutes
without
either
a
drive
or
a
filler
panel
installed
in
each
drive
bay.
v
All
hot-swap
drives
in
the
server
must
have
the
same
speed
rating;
if
you
mix
speed
ratings,
all
drives
will
operate
at
the
speed
of
the
slowest
drive.
v
You
do
not
have
to
turn
off
the
server
to
install
hot-swap
drives
in
the
hot-swap
drive
bays.
v
Set
the
drive
jumpers
either
to
disable
auto-start
or
to
delay
startup,
to
prevent
overtaxing
the
system
power
supply
by
all
drives
trying
to
spin
up
at
once.
v
Install
hot-swap
hard
disk
drives
in
this
sequence:
bay
9,
bay
8,
bay
7,
bay
6,
bay
5,
and
bay
4.
v
If
the
server
has
an
optional
RAID
adapter,
see
the
documentation
that
comes
with
the
adapter
for
instructions
for
installing
a
hard
disk
drive.
40
xSeries
226
Type
8488
and
8648:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Содержание 84885BU
Страница 1: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 2: ......
Страница 3: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 10: ...Index 183 viii xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 34: ...24 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 106: ...96 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 163: ...Appendix B Safety information 153 ...
Страница 164: ...154 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 165: ...Appendix B Safety information 155 ...
Страница 166: ...156 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 167: ...Appendix B Safety information 157 ...
Страница 168: ...158 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 169: ...Appendix B Safety information 159 ...
Страница 179: ...Appendix B Safety information 169 ...
Страница 180: ...170 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 181: ...Appendix B Safety information 171 ...
Страница 182: ...172 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 186: ...176 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 198: ...188 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 199: ......
Страница 200: ... Part Number 25K8108 Printed in USA 1P P N 25K8108 ...