Power
error
messages
Note:
See
“System
replaceable
units”
on
page
131
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
Power
supply
x
current
share
fault
(level-critical;
excessive
current
demand
on
power
supply
x)
v
Replace
power
supply
x
.
Power
supply
x
DC
good
fault
(level-critical;
power
good
signal
not
detected
for
power
supply
x
)
v
Replace
power
supply
x
.
Power
supply
x
temperature
fault
v
Replace
power
supply
x
.
Power
supply
x
removed
v
No
action
required
–
information
only.
Power
supply
x
fan
fault
(level-critical;
fan
fault
in
power
supply
x
)
v
Replace
power
supply
x
.
Power
supply
x
12
V
fault
(level-critical;
overcurrent
condition
detected)
v
See
“Power
checkout”
on
page
21.
Power
supply
x
3.3
V
fault
(level-critical;
3.3
V
power
supply
x
had
an
error)
v
See
“Power
checkout”
on
page
21.
Power
supply
x
5
V
fault
(level-critical;
5
V
power
supply
x
had
an
error)
v
See
“Power
checkout”
on
page
21.
System
running
non-redundant
power
(level-noncritical;
system
does
not
have
redundant
power)
1.
Add
another
power
supply.
2.
Remove
options
from
system.
3.
System
can
continue
to
operate
without
redundancy
protection
if
steps1
and
2
are
not
followed.
System
under
recommended
voltage
for
x
(level-warning;
indicated
voltage
supply
under
nominal
value;
value
for
x
can
be
+12,
-12,
or
+5)
1.
Check
connections
to
the
power
subsystem.
2.
Power
supply.
3.
Power
cage
assembly,
if
installed.
System
shutdown
See
the
following
tables
when
experiencing
system
shutdown
related
to
voltage
or
temperature
problems.
Voltage-related
system
shutdown
Note:
See
“System
replaceable
units”
on
page
131
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
System
shutoff
due
to
x
current
over
max
value
(level-critical;
system
drawing
too
much
current
on
voltage
x
bus)
v
See
“Power
checkout”
on
page
21.
System
shutoff
due
to
x
V
over
voltage
(level-critical;
system
shutoff
due
to
x
supply
over
voltage)
1.
Check
the
power-supply
connectors.
2.
Power
supply.
3.
Power
cage
assembly,
if
installed.
124
xSeries
226
Type
8488
and
8648:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Содержание 84885BU
Страница 1: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 2: ......
Страница 3: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 10: ...Index 183 viii xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 34: ...24 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 106: ...96 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 163: ...Appendix B Safety information 153 ...
Страница 164: ...154 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 165: ...Appendix B Safety information 155 ...
Страница 166: ...156 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 167: ...Appendix B Safety information 157 ...
Страница 168: ...158 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 169: ...Appendix B Safety information 159 ...
Страница 179: ...Appendix B Safety information 169 ...
Страница 180: ...170 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 181: ...Appendix B Safety information 171 ...
Страница 182: ...172 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 186: ...176 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 198: ...188 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 199: ......
Страница 200: ... Part Number 25K8108 Printed in USA 1P P N 25K8108 ...