Specifications (system)
The following table contains the environmental
specifications for the Netfinity 3000 server.
Notes
1. The following levels were measured in controlled
acoustical environments according to procedures
specified by the American National Standards
Institute (ANSI) S12.10 and ISO 7779, and are
reported in accordance with ISO 9296.
2. Actual sound-pressure levels in your location
might exceed the average values stated because
of room reflections and other nearby noise
sources. The declared sound power levels
indicate an upper limit, below which a large
number of computers will operate.
Size
Depth: 445 mm (17.5 in.)
Width: 200 mm (7.9 in.)
Height: 492 mm (19.4 in.)
Weight
Maximum configuration (as shipped): 17.3 kg (38 lb)
Standard configuration (as shipped): 15 kg (33 lb)
Environment
Air temperature:
–
System on: 10° to 35°C (50° to 95°F) at altitude 0–915 m (3000 ft)
10° to 32°C (50° to 90°F) at altitude 915–2134 m
(3000–7000 ft)
–
System off: 10° to 43°C (50° to 110°F)
Humidity:
–
System on: 8% to 80%
–
System off: 8% to 80%
Heat Output
Approximate heat output in British thermal units (Btu) per hour:
–
Maximum configuration (as shipped): 306 Btu/hour (90 watts)
–
Maximum configuration (theoretical)1: 1564 Btu/hour (460 watts)
Electrical Input
Sine-wave input (50/60 Hz) is required
Input voltage:
–
Low range:
-
Minimum: 90 V ac
-
Maximum: 137 V ac
–
High range:
-
Minimum: 180 V ac
-
Maximum: 265 V ac
–
Input kilovolt-amperes (kVA) (approximately):
-
Maximum (configuration as shipped): 0.70 kVA
Power consumption and heat output vary depending on the number and type
of optional features installed and the power-management optional features in
use.
Acoustical Noise-Emission Values
Average sound-pressure levels:
–
At operator position:
-
35 dBA idle
-
40 dBA operating
1
Under typical maximum configurations, the heat output will be
substantially below the theoretical maximum.
56
Netfinity Server HMM
Содержание 847620U - Netfinity 3000 - 20U
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM ...
Страница 145: ...Caution Use safe lifting practices when lifting the machine IBM Netfinity 3000 Type 8476 137 ...
Страница 218: ...210 Netfinity Server HMM ...
Страница 238: ...230 Netfinity Server HMM ...
Страница 239: ...Related service information 231 ...
Страница 240: ...232 Netfinity Server HMM ...
Страница 241: ...Related service information 233 ...
Страница 242: ...234 Netfinity Server HMM ...
Страница 255: ...Related service information 247 ...
Страница 256: ...248 Netfinity Server HMM ...
Страница 257: ...Related service information 249 ...
Страница 269: ......
Страница 270: ...IBM Part Number 19K2484 Printed in U S A S1ðL 9798 ð5 ...