conflict occurs, and the device will remain deactivated
by the configuration program.
4. Change system board jumpers or switches. Then,
refer to the system board diagram inside the server.
5. Remove the device or adapter. Some configurations
are not supported. If you must remove an adapter,
see “Installing or removing ISA and PCI adapters” on
page 62.
Software configuration conflicts
:
The Configuration/Setup utility might change the
memory-address space used by some hardware options.
If this happens, the new memory-address space and IRQs
used by some hardware options might conflict with
addresses defined for use through application programs.
If a conflict exists, one or more of the following conditions
might exist:
The system cannot load the operating system.
The system does not work.
An application program does not operate, or it returns
an error.
Screen messages indicate that a memory-address
conflict exists.
Note
Start the Configuration/Setup Utility program to view
the addresses that are used by the system board
functions.
The best way to resolve memory-address conflicts is to
change the addresses that are used by the application
program or the device driver. You can use the
Configuration/Setup Utility program to view and change
addresses.
Configuration/Setup utility program
For most configurations, the server will operate using the
default system settings. You need to change the settings
only to resolve configuration conflicts or to enable or
change device functions.
When you want or need to change the default settings, the
Configuration/Setup Utility program provides a convenient
way to display and change the settings.
After you run and exit the Configuration/Setup Utility
program, configuration information is stored in electrically
erasable programmable read-only memory (EEPROM).
While the server is powered off, the configuration
information remains available for the next system startup.
Always run the Configuration/Setup Utility program if you
receive an error message instructing you to do so. If you
installed or removed SCSI devices, run the SCSISelect
IBM Netfinity 3000 - Type 8476
21
Содержание 847620U - Netfinity 3000 - 20U
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM ...
Страница 145: ...Caution Use safe lifting practices when lifting the machine IBM Netfinity 3000 Type 8476 137 ...
Страница 218: ...210 Netfinity Server HMM ...
Страница 238: ...230 Netfinity Server HMM ...
Страница 239: ...Related service information 231 ...
Страница 240: ...232 Netfinity Server HMM ...
Страница 241: ...Related service information 233 ...
Страница 242: ...234 Netfinity Server HMM ...
Страница 255: ...Related service information 247 ...
Страница 256: ...248 Netfinity Server HMM ...
Страница 257: ...Related service information 249 ...
Страница 269: ......
Страница 270: ...IBM Part Number 19K2484 Printed in U S A S1ðL 9798 ð5 ...