Ethernet controller messages
Note
The following error messages are available only with
the integrated Ethernet controller. These error
messages are not available when remote program
load (RPL) or dynamic host configuration protocol
(DHCP) is used through optional network adapters.
If a failure condition occurs after the Ethernet controller is
initialized, one or more of the following error messages will
be displayed on the screen.
The two most common error messages are:
RPL-ROM-ERR: 1ð5 The integrated Ethernet
failed the loopback test.
RPL-ROM-ERR: 1ð7 The media test failed.
Error 105 indicates that a power-on diagnostic test
performed by the Ethernet module did not execute
correctly. If this error message appears, replace the
system board. Error 107 indicates that the cable from the
LAN is not securely connected to the Ethernet port on the
server. Check the cable to ensure that it is properly
connected.
Other error messages that might occur are shown in
Table 12 on page 190.
Note
An
x value that follows an error code represents any
alphanumeric character.
IBM Netfinity 3000 - Type 8476
189
Содержание 847620U - Netfinity 3000 - 20U
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM ...
Страница 145: ...Caution Use safe lifting practices when lifting the machine IBM Netfinity 3000 Type 8476 137 ...
Страница 218: ...210 Netfinity Server HMM ...
Страница 238: ...230 Netfinity Server HMM ...
Страница 239: ...Related service information 231 ...
Страница 240: ...232 Netfinity Server HMM ...
Страница 241: ...Related service information 233 ...
Страница 242: ...234 Netfinity Server HMM ...
Страница 255: ...Related service information 247 ...
Страница 256: ...248 Netfinity Server HMM ...
Страница 257: ...Related service information 249 ...
Страница 269: ......
Страница 270: ...IBM Part Number 19K2484 Printed in U S A S1ðL 9798 ð5 ...