Table 3. System memory configuration for independent channel mode
(1 microprocessor)
(continued)
Installed
memory
DIMM socket
1
2
3
4
5
6
7
8
9
10
11
12
4 DIMMs
X
X
X
X
5 DIMMs
X
X
X
X
X
6 DIMMs
X
X
X
X
X
X
Table 4. System memory configuration for independent channel mode
(2 microprocessors)
Installed
memory
DIMM socket
1
2
3
4
5
6
7
8
9
10
11
12
2 DIMMs
X
X
3 DIMMs
X
X
X
4 DIMMs
X
X
X
X
5 DIMMs
X
X
X
X
X
6 DIMMs
X
X
X
X
X
X
7 DIMMs
X
X
X
X
X
X
X
8 DIMMs
X
X
X
X
X
X
X
X
9 DIMMs
X
X
X
X
X
X
X
X
X
10 DIMMs
X
X
X
X
X
X
X
X
X
X
11 DIMMs
X
X
X
X
X
X
X
X
X
X
X
12 DIMMs
X
X
X
X
X
X
X
X
X
X
X
X
v
Mirrored channel mode:
In mirrored channel mode, channels 2 and 5 are
unused. The memory contents on channel 0 are duplicated in channel 1, and the
memory contents of channel 3 are duplicated in channel 4. The effective memory
available to the system is only half of that installed. The maximum available
memory (with 16 GB DIMMs) is 32 GB for a single CPU system and 64 GB for a
dual CPU system.
Important:
The memory configuration of channel 0 must match that of channel
1, and the memory configuration of channel 3 must match that of channel 4. For
example, if a 4 GB Dual Rank DIMM is installed into the DIMM2 connector,
then a 4 GB Dual Rank DIMM must also be installed into the DIMM6 connector.
Table 2 on page 65 lists each channel and which DIMM connectors belong to the
channel.
The following table shows the order that memory DIMMs are installed to use a
mirrored channel mode.
Table 5. System memory configuration for mirrored channel mode
(1 microprocessor)
Installed
memory
DIMM socket
1
2
3
4
5
6
7
8
9
10
11
12
2 DIMMs
X
X
4 DIMMs
X
X
X
X
66
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Содержание 7870B4U
Страница 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 265: ...W Web site ServerGuide 31 Windows IPMI device driver 38 WOL disable switch 17 wrong characters 170 Index 251...
Страница 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 267: ......
Страница 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...