Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error Code
Type
Error Message
Action
0x806F0813
Error
Group grou 2 (Critical Int) bus
uncorrectable error
1.
Check the operating system event log and the
system event log as it may contain additional
information (see “Error logs” on page 103).
2.
Reseat the blade server in the BladeCenter (see
“Removing the blade server from the BladeCenter
unit” on page 52 and “Installing the blade server
in a BladeCenter unit” on page 53).
3.
Update the device drivers for any expansion cards
that are installed into the blade server.
4.
Reseat the expansion card (see “Removing an I/O
expansion card” on page 71 and “Installing an
I/O expansion card” on page 75).
5.
Replace the expansion card (see “Removing an
I/O expansion card” on page 71 and “Installing
an I/O expansion card” on page 75).
0x806F0813
Error
Group 1 (Critical Int) bus
uncorrectable error
1.
Make sure that the latest firmware is being used
(see “Firmware updates” on page 34).
2.
Reseat the blade server in the BladeCenter unit
(see “Removing the blade server from the
BladeCenter unit” on page 52 and “Installing the
blade server in a BladeCenter unit” on page 53).
3.
Run the Setup utility and load the default system
settings (see “Using the Setup utility” on page 21).
4.
Check the event logs for other related error
messages (see “Error logs” on page 103).
5.
(Trained service technician only) If the error
continues, replace the system-board assembly (see
“Removing the system-board assembly” on page
97 and “Installing the system-board assembly” on
page 98).
0x806F0813
Error
Group 4 (Critical Int) bus
uncorrectable error
1.
Verify that the system is running the latest UEFI
firmware (see “Firmware updates” on page 34).
2.
(Trained service technician only) If the error
continues, replace the system-board assembly (see
“Removing the system-board assembly” on page
97 and “Installing the system-board assembly” on
page 98).
Chapter 6. Diagnostics
145
Содержание 7870B4U
Страница 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 265: ...W Web site ServerGuide 31 Windows IPMI device driver 38 WOL disable switch 17 wrong characters 170 Index 251...
Страница 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Страница 267: ......
Страница 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...