b) Remove the USB cable from the power distribution board and from the control panel.
Use your thumb or finger to press the release latch on the connector to remove the cable. Unclip
the cable from the right air baffle.
Figure 7. Disconnecting the USB cable
Replacing the USB cable in the 7063-CR2 system
To replace the USB cable in the IBM Power Systems HMC (7063-CR2) system, complete the steps in this
procedure.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. Replace the USB cable.
a) Using your labels, replace the USB cable into the power distribution board and into the control
panel.
Ensure that the cable latch clip snaps into place on the connector.
b) Route the cable through the right air baffle channel; the USB cable nests inside the control panel
cable.
Clip the cable into the right air baffle.
Figure 8. Connecting the USB cable
3. Install the service access cover.
For instructions, see “Installing the service access cover on a 7063-CR2 system” on page 105.
4. Replace the system in the rack and replace the components that you removed.
For instructions, see “Placing a 7063-CR2 system into the operating position” on page 103.
5. Power on the system for operation.
For instructions, see “Starting the 7063-CR2 system ” on page 98.
Removing and replacing a drive in the 7063-CR2
Learn how to remove and replace a drive in the IBM Power Systems HMC (7063-CR2) system.
About this task
The system has two physical drives. These drives are configured as a single virtual drive, as a RAID1 array.
The drives have an ID of 0. If one of the drives needs to be replaced, use the “Drive commands for the
7063-CR2 system” on page 99 to check the status of the drives, the IDs of the drives, and to rebuild the
RAID1 array. The drive can be replaced with power on; the HMC continues to function normally.
10 Power Systems: Servicing the IBM Power Systems HMC (7063-CR2)