Figure 10. Installing a drive
3. The drive rebuild operation starts automatically.
Removing and replacing the drive holder in the 7063-CR2
Learn how to remove and replace the drive holder in the IBM Power Systems HMC (7063-CR2) system.
Removing the drive holder from the 7063-CR2 system
To remove the drive holder from the IBM Power Systems HMC (7063-CR2) system, complete the steps in
this procedure.
About this task
You can use a magnetic tip screwdriver to remove and replace the screws.
Procedure
1. Attach the electrostatic discharge (ESD) wrist strap.
The ESD wrist strap must be connected to an unpainted metal surface until the service procedure is
completed, and if applicable, until the service access cover is replaced.