Code
Description
Action
190
The computer chassis-intrusion
detector was cleared.
This is an informational
message. No action is
required.
20x
A memory error occurred.
Go to “IBM Enhanced
Diagnostics” on page 123 for
instructions for running
diagnostics.
301 or
303
A keyboard error occurred.
1. Make sure the keyboard is
properly connected.
2. If the keyboard is properly
connected, have the
computer serviced.
601
A diskette drive or controller
error occurred.
1. Go to “IBM Enhanced
Diagnostics” on page 123
and if possible follow the
instructions to run the
Enhanced Diagnostics.
2. Have the computer
serviced.
602
The diskette IPL startup (boot)
record is not valid.
1. The diskette might be
defective. Try another
diskette.
2. If the problem persists,
have the computer
serviced.
604
An unsupported diskette drive
is installed.
1. Go to “IBM Enhanced
Diagnostics” on page 123
and if possible follow the
instructions to run the
Enhanced Diagnostics.
2. Have the computer
serviced.
662
Diskette drive configuration
error
1. Go to Chapter 4, “Using
the Configuration/Setup
Utility program” on
page 43 and follow the
instructions to view the
configuration settings.
Verify the diskette drive
configuration.
2. Run the diagnostics
program for the diskette
drive. See “IBM Enhanced
Diagnostics” on page 123.
3. If the problem persists,
have the computer
serviced.
Chapter 6. Troubleshooting
103
Содержание 6868 - IntelliStation M - Pro
Страница 1: ...User Guide IntelliStation M Pro Type 6868 Professional Workstation...
Страница 2: ......
Страница 3: ...User Guide IntelliStation M Pro Type 6868 Professional Workstation IBM...
Страница 24: ...10 IntelliStation User Guide...
Страница 38: ...24 IntelliStation User Guide...
Страница 110: ...96 IntelliStation User Guide...
Страница 154: ...140 IntelliStation User Guide...
Страница 160: ...146 IntelliStation User Guide...
Страница 180: ...166 IntelliStation User Guide...
Страница 188: ...IBM Part Number 37L2184 Printed in U S A October 1999 37L2184...