Threshold values written in NVRAM display:
Cx1 Fx2 Rx3(x4)
where:
v
x1 is the threshold for manual path
v
x2 is the threshold for front path
v
x3 is the threshold for rear path and rollers closed
v
x4 is the threshold for rear path and rollers open
v
x1, x2, x3, x4 are numbers in hexadecimal format corresponding to the threshold voltages with resolution
of 20 mV.
Press the Micro
↓
key to go to step 7.
7. The following displays:
Y SENSOR LEVEL N
This part of the test is intended for use by Product Engineering. It allows the user to examine sensor output
voltages.
8. Press the Load/Form Feed key to skip to step 9.
Press the Micro
↑
key to enter.
The current sensor measurements display:
C:x1 F:x2 R:x3
where:
v
x1 is manual path measurement
v
x2 is front path measurement
v
x3 is rear path measurement
Chapter 2. Diagnostics
188
Содержание 4247
Страница 1: ...4247 Printers Maintenance Information Document Number SA24 4400 05 Part Number 27P8450 IBM ...
Страница 241: ...e90apc15 Figure 24 Main Input Power Supply Ground Chapter 3 Circuit Diagrams 241 ...
Страница 257: ...Figure 32 Stacker Motor Wiring Chapter 3 Circuit Diagrams 257 ...
Страница 261: ...Stacker Cable Wiring Figure 36 Tractor Assembly Cable Wiring Chapter 3 Circuit Diagrams 261 ...
Страница 266: ...Locations and Orientations Logic Board Microcode Module Locations and Orientation Model A00 Chapter 4 Locations 266 ...
Страница 348: ...7 Remove the side cover screws and side covers Figure 96 Top Cover Chapter 5 Removals and Adjustments 348 ...
Страница 498: ...Table 75 Store Mode Quit Save Current Manufacturing Default Appendix A Printer Configuration 498 ...
Страница 501: ...E90AX003 Figure 196 Coax Configuration Printout Part 1 of 2 Appendix A Printer Configuration 501 ...