Table 11. MAP 0150: Power Supply (continued)
Questions/Actions
Yes
No
4. a. Power off (O) the printer.
b. Connect the power supply fan to the power
supply board.
c. Power on (|) the printer.
Does the power supply fan run OK?
Go to step 5.
Power off (O) the printer.
Install a new power supply fan.
- or -
Install a new power supply. See “Power
Supply” on page 400.
Run T&D in automatic mode to verify
correct printer operation. For Model
A00, see “How To Run the Test and
Diagnostic (T&D) Programs” on
page 161. For Models 001, 002, or 003,
see “How To Run the Test and
Diagnostic (T&D) Programs” on
page 201.
5. a. Power off (O) the printer.
b. Connect the power supply cable to the logic
board.
c. Power on (|) the printer.
Does the power supply fan run OK?
Go to step 6 on page 79.
Go to step 7 on page 80.
Chapter 1. Diagnosing Problems
78
Содержание 4247
Страница 1: ...4247 Printers Maintenance Information Document Number SA24 4400 05 Part Number 27P8450 IBM ...
Страница 241: ...e90apc15 Figure 24 Main Input Power Supply Ground Chapter 3 Circuit Diagrams 241 ...
Страница 257: ...Figure 32 Stacker Motor Wiring Chapter 3 Circuit Diagrams 257 ...
Страница 261: ...Stacker Cable Wiring Figure 36 Tractor Assembly Cable Wiring Chapter 3 Circuit Diagrams 261 ...
Страница 266: ...Locations and Orientations Logic Board Microcode Module Locations and Orientation Model A00 Chapter 4 Locations 266 ...
Страница 348: ...7 Remove the side cover screws and side covers Figure 96 Top Cover Chapter 5 Removals and Adjustments 348 ...
Страница 498: ...Table 75 Store Mode Quit Save Current Manufacturing Default Appendix A Printer Configuration 498 ...
Страница 501: ...E90AX003 Figure 196 Coax Configuration Printout Part 1 of 2 Appendix A Printer Configuration 501 ...