Table 27. T&D Error Messages and Action (continued)
Error Message
Description
Action
TD 5 FRU 1 X
Operator Panel Failure
1. This error can occur if a key is not
pressed in less than 10 seconds.
Run T&D05 again to verify the
problem.
2. Replace the operator panel.
See “Operator Panel” on page 355.
3. Replace the logic board.
See “Logic Board - Model A00” on
page 370.
4. Replace the operator panel cable.
TD 6 FRU 0 X (*)
Parallel Interface
Failure
Replace the logic board.
See “Logic Board - Model A00” on
page 370.
TD 8 FRU 0 X
Microcode Error
Replace the logic board.
See “Logic Board - Model A00” on
page 370.
TD 9 FRU 0 X (*)
Serial Attachment
Failure
1. Replace the logic board.
See “Logic Board - Model A00” on
page 370.
2. Replace the serial attachment card.
See “Serial Attachment Card -
Model A00” on page 390.
TD 10 FRU 0 1 (*)
ASF/Stacker Failure
1. Replace the logic board.
See “Logic Board - Model A00” on
page 370.
2. Replace the stacker cable
assembly.
Chapter 2. Diagnostics
191
Содержание 4247
Страница 1: ...4247 Printers Maintenance Information Document Number SA24 4400 05 Part Number 27P8450 IBM ...
Страница 241: ...e90apc15 Figure 24 Main Input Power Supply Ground Chapter 3 Circuit Diagrams 241 ...
Страница 257: ...Figure 32 Stacker Motor Wiring Chapter 3 Circuit Diagrams 257 ...
Страница 261: ...Stacker Cable Wiring Figure 36 Tractor Assembly Cable Wiring Chapter 3 Circuit Diagrams 261 ...
Страница 266: ...Locations and Orientations Logic Board Microcode Module Locations and Orientation Model A00 Chapter 4 Locations 266 ...
Страница 348: ...7 Remove the side cover screws and side covers Figure 96 Top Cover Chapter 5 Removals and Adjustments 348 ...
Страница 498: ...Table 75 Store Mode Quit Save Current Manufacturing Default Appendix A Printer Configuration 498 ...
Страница 501: ...E90AX003 Figure 196 Coax Configuration Printout Part 1 of 2 Appendix A Printer Configuration 501 ...