Note:
When installed, each N6000 series filer enclosure will occupy a 6U space.
Using two silver pan head M5 screws, attach the rail to the front of the rack using holes H2 and H8.
Tighten these screws with a screwdriver.
3.
At the rear of the rack, position the rail at the same EIA location used in step 2. Make sure that the
locating pins seat properly. Using two silver pan head M5 screws, attach the rail to the rack using
holes H2 and H8. Tighten these screws with a screwdriver.
4.
Tighten the four rail adjustment screws on the installed rail.
5.
Repeat steps 2 through 4 for the left-hand rail.
Installing the system in the rack
Use these instructions to install the N6000 series filer in the rack.
H1
H2
H3
H4
H5
H6
H7
H8
H9
H1
H2
H3
H4
H5
H6
H7
H8
H9
Bottom rail screws
Chassis attach screw
Locating pins
Locating pins
Chassis attach screw
1 EIA unit (1U)
Top rail screws
REAR
Left and Right
Rails
Section of rack EIA rail
FRONT
Left and Right
Rails
n600004
Figure 3. N6000 rail mounting template
Installation and setup instructions
5