POST error codes
Use this information to diagnose and resolve POST error codes for the blade
server.
The following table describes the POST error codes and suggested actions to
correct the detected problems.
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are customer replaceable units
(CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
0010002
Microprocessor not supported.
1.
Reseat the following components one at a time in
the order shown, restarting the server each time:
v
(Trained service technician) Microprocessor 1
(see “Removing a microprocessor and heat
sink” on page 90 and “Installing a
microprocessor and heat sink” on page 94).
v
(Trained service technician) Microprocessor 2,
if installed (see “Removing a microprocessor
and heat sink” on page 90 and “Installing a
microprocessor and heat sink” on page 94).
2.
(Trained service technician) Complete the
following steps:
a.
Remove microprocessor 2 and restart the
server (see “Removing a microprocessor and
heat sink” on page 90 and “Installing a
microprocessor and heat sink” on page 94).
b.
If the problem remains, remove
microprocessor 1 and install microprocessor 2
in the connector for microprocessor 1; then,
restart the server (see “Removing a
microprocessor and heat sink” on page 90 and
“Installing a microprocessor and heat sink” on
page 94).
c.
If the problem goes away, microprocessor 1
might have failed; replace the microprocessor.
3.
Replace the following components one at a time
in the order shown, restarting the server each
time:
v
(Trained service technician) Microprocessor 1
(see “Removing a microprocessor and heat
sink” on page 90 and “Installing a
microprocessor and heat sink” on page 94).
v
(Trained service technician) Microprocessor 2,
if installed (see “Removing a microprocessor
and heat sink” on page 90 and “Installing a
microprocessor and heat sink” on page 94).
v
(Trained service technician) System board (see
“Removing the system-board assembly” on
page 97 and “Installing the system-board
assembly” on page 98).
146
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Содержание 1911
Страница 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 265: ...W Web site ServerGuide 31 Windows IPMI device driver 38 WOL disable switch 17 wrong characters 170 Index 251 ...
Страница 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 267: ......
Страница 268: ... Part Number 90Y5614 Printed in USA 1P P N 90Y5614 ...