v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
201-877-xxx
Aborted the memory self test because the
Mirroring feature is enabled.
1.
If the blade server has stopped responding, turn
off and restart the blade server. See “Turning off
the blade server” on page 14, “Turning on the
blade server” on page 14.
2.
Press F1 during start up and turn off the
Mirroring feature; then, rerun the test. See
“Diagnostic tools overview” on page 101.
3.
Make sure that the system BIOS firmware is at
the latest level, upgrade if necessary; then, rerun
the test (“Diagnostic tools overview” on page
101). The BIOS firmware level can be found in
the DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found on the IBM support Web site at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-63017.
4.
If the component failure remains, refer to
Chapter 5, “Removing and replacing blade
server components,” on page 49 to replace the
failed component.
201-878-xxx
Aborted the memory self test because the
Sparing feature is enabled.
1.
If the blade server has stopped responding, turn
off and restart the blade server. See “Turning off
the blade server” on page 14, “Turning on the
blade server” on page 14.
2.
Press F1 during start up and turn off the
Sparing feature; then, rerun the test. See
“Diagnostic tools overview” on page 101.
3.
Make sure that the system BIOS firmware is at
the latest level, upgrade if necessary; then, rerun
the test (“Diagnostic tools overview” on page
101). The BIOS firmware level can be found in
the DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found on the IBM support Web site at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-63017.
4.
If the component failure remains, refer to
Chapter 5, “Removing and replacing blade
server components,” on page 49 to replace the
failed component.
212
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Содержание 1911
Страница 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 265: ...W Web site ServerGuide 31 Windows IPMI device driver 38 WOL disable switch 17 wrong characters 170 Index 251 ...
Страница 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 267: ......
Страница 268: ... Part Number 90Y5614 Printed in USA 1P P N 90Y5614 ...