v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error Code
Type
Error Message
Action
0x80010200
Error
Expansion Module 1 (BPE3
12VSB Sense) voltage under
critical threshold. Reading:
X
,
Threshold:
Y
1.
If the under voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events (see
“Error logs” on page 103).
2.
View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3.
If other modules or blades are logging the same
issue; then, check the power supply for the
BladeCenter unit.
4.
If the base blade is not logging a power issue;
then, replace the Blade PCI Express I/O
expansion unit. See “Removing an optional
expansion unit” on page 84 and “Installing an
optional expansion unit” on page 85.
0x80010200
Error
Expansion Module 1 (BPE3 3.3V
Sense) voltage under critical
threshold. Reading:
X
,
Threshold:
Y
1.
If the under voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events (see
“Error logs” on page 103).
2.
View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3.
If the base blade is not logging a power issue;
then, replace the Blade PCI Express I/O
expansion unit. See “Removing an optional
expansion unit” on page 84 and “Installing an
optional expansion unit” on page 85.
0x80010200
Error
System board (Planar 12V)
voltage under critical threshold.
with chassis Reading:
X
,
Threshold:
Y
1.
If the under voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events (see
“Error logs” on page 103).
2.
View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3.
If other modules or blades are logging the same
issue then check the power supply for the
BladeCenter unit.
4.
If the error still occurs, replace the system-board
assembly (see “Removing the system-board
assembly” on page 97 and “Installing the
system-board assembly” on page 98).
106
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Содержание 1911
Страница 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 265: ...W Web site ServerGuide 31 Windows IPMI device driver 38 WOL disable switch 17 wrong characters 170 Index 251 ...
Страница 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide ...
Страница 267: ......
Страница 268: ... Part Number 90Y5614 Printed in USA 1P P N 90Y5614 ...