background image

USER’S INFORMATION MANUAL

2

SL SERIES BOILERS

SAFETY CONSIDERATIONS

Installation, start-up and servicing of IBC boilers must be done with due 

care and attention, and should only be performed by competent, qualified, 

licensed and trained heating technicians. Failure to read and comply with 

all instructions and applicable National and local codes may result in 

hazardous conditions that could result in property damage and injury to 

occupants which in extreme cases might result in death.

HAZARDS & PRECAUTIONS

WARNING

If the information in this 

manual is not followed 

exactly, a fire or explosion 

may result causing property 

damage, personal injury, or 

loss of life.

WARNING

Points out a potentially 

hazardous situation which 

must be avoided to prevent 

serious injury or death.

CAUTION

Points out a potentially 

hazardous situation which 

must be avoided to prevent 

possible moderate injury and/

or property damage

NOTE

Points out installation, 

maintenance and operation 

details that will result in 

enhanced efficiency, longevity 

and proper operation of your 

boiler.

DANGER

Points out an immediately 

hazardous situation which 

must be avoided in order to  

prevent serious injury or 

death.

BEST PRACTICES

Points out recommendations 

for better installation.

Содержание SL SERIES

Страница 1: ...pliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a nearby phone Fo...

Страница 2: ...information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Points out a potentially hazardous situation which mu...

Страница 3: ...3 USER S INFORMATION MANUAL SL SERIES BOILERS WARNINGS 3 IBC BOILER CONTROLLER 6 LIGHTING AND SHUTTING DOWN THE BOILER 8 MAINTENANCE 9 SERVICE RECORD 11 CONTENTS...

Страница 4: ...llows Acidity pH is to be between 6 5 and 8 5 Chloride is to be less than 125 mg l Iron is to be less than 0 3 mg l Cu less than 0 1 mg l Conductivity is to be less than 400 S cm at 25 C Hardness is t...

Страница 5: ...tible materials gasoline and other flammable vapours and liquids WARNING Combustion air must not be drawn from areas containing corrosive air from swimming pools or spas including air directly next to...

Страница 6: ...e Home Screen Internet LAN connectivity BACnet with activation Control When the boiler is first energized the controller will go through a power up sequence that will take approximately 90 seconds Dur...

Страница 7: ...play will be showing the Home screen that includes details of the current boiler status If the controller has been left on the Home screen long enough user adjustable 10 minutes by default the display...

Страница 8: ...USER S INFORMATION MANUAL 8 SL SERIES BOILERS LIGHTING AND SHUTTING DOWN THE BOILER clockwise open close...

Страница 9: ...r and vacuum if required Check for water gas and condensate leaks in the boiler and around the boiler Check the condensate trap and clean if required Re fill the trap and re install the trap hook Chec...

Страница 10: ...chemicals or glycol solutions If the system employs plain water the boiler auto fill valve must be turned on in order to recharge the lost fluid Blocked Vent Safety System The boiler is equipped with...

Страница 11: ...11 USER S INFORMATION MANUAL SL SERIES BOILERS SERVICE RECORD DATE LICENSED CONTRACTOR DESCRIPTION OF WORK DONE...

Страница 12: ...USER S INFORMATION MANUAL 12 SL SERIES BOILERS NOTES...

Страница 13: ...13 USER S INFORMATION MANUAL SL SERIES BOILERS NOTES...

Страница 14: ...E MUST NOT BE USED UNLESS AT LEAST ONE OF THE FOLLOWING CONDITIONS IS TRUE An external energy management system is installed that reduces the boiler water temperature as the heating load decreases Thi...

Страница 15: ...REVISION HISTORY R1 JULY 2014 Initial release R2 MAY 2015 Address update...

Страница 16: ...IBC Technologies Inc 8015 North Fraser Way Burnaby BC Canada V5J 5M8 Tel 604 877 0277 Fax 604 877 0295 www ibcboiler com 120 203 A R2 May 2015 IBC Technologies Inc 2015...