USER’S INFORMATION MANUAL

4

SL SERIES BOILERS

WARNING

Close fill valve after any 

addition of water to the 

system, to reduce risk of 

water escapement.

WARNING

Water quality has a significant 

impact on the lifetime and 

performance of an IBC Boiler 

heat exchanger.
Improperly prepared water in 

a heating circuit may cause 

damage to the heat exchanger 

through corrosion or fouling. 

Repeated or uncontrolled 

water fills will increase the 

potential for damage.
High levels of dissolved 

solids or minerals may 

precipitate out of the fluid 

onto the hottest part of the 

heat exchanger, impairing 

heat transfer and resulting in 

overheating and premature 

failure. The amount of solids 

that may form on the heat 

exchanger will depend on 

the degree of hardness and 

the total water volume in the 

system. A high water volume 

system with a low hardness 

count may cause as much 

damage as a system with less 

volume and higher hardness, 

so it is recommended to treat 

water so as to remove all 

dissolved solids. Other water 

chemistry allowable limits are 

as follows:

 

Acidity pH is to be between 

6.5 and 8.5

 

Chloride is to be less than 

125 mg/l

 

Iron is to be less than 0.3 

mg/l

 

Cu less than 0.1 mg/l

 

Conductivity is to be less 

than 400μS/cm (at 25°C)

 

Hardness is to be 7 Grains 

or less

IMPORTANT: Ensure that 

these limits are acceptable 

for the other water-side 

components in the system.

WARNING

HOT WATER CAN SCALD!
Water Temperatures over 

125°F / 52°C can cause severe 

burns instantly or death from 

scalds.
Children, disabled, and 

elderly are at highest risk of 

being scalded.

•  Never leave then 

unattended in or near the 

shower, bathtub or sink.

•  Never allow small children 

to use a not water faucet or 

draw their own bath.

To avoid any potential scald 

hazard or if codes require 

specific water temperatures 

at the hot water faucet, the 

installer must:

 

Install a thermostatic mixing 

valve at the outlet of the 

Domestic Hot Water Indirect 

Water Heater outlet and 

ensure it is working properly.

 

AND

 

Set the thermostatic 

mixing valve to the lowest 

temperature which satisfies 

your hot water needs.

TO AVOID INJURY:

 

Feel and adjust water 

temperature before bathing 

or showering.

 

Water drained from the 

system drain valve may be 

extremely hot.

 

Make sure all connections 

are tight.

 

Direct water flow away from 

any person.

Содержание SL SERIES

Страница 1: ...pliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a nearby phone Fo...

Страница 2: ...information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Points out a potentially hazardous situation which mu...

Страница 3: ...3 USER S INFORMATION MANUAL SL SERIES BOILERS WARNINGS 3 IBC BOILER CONTROLLER 6 LIGHTING AND SHUTTING DOWN THE BOILER 8 MAINTENANCE 9 SERVICE RECORD 11 CONTENTS...

Страница 4: ...llows Acidity pH is to be between 6 5 and 8 5 Chloride is to be less than 125 mg l Iron is to be less than 0 3 mg l Cu less than 0 1 mg l Conductivity is to be less than 400 S cm at 25 C Hardness is t...

Страница 5: ...tible materials gasoline and other flammable vapours and liquids WARNING Combustion air must not be drawn from areas containing corrosive air from swimming pools or spas including air directly next to...

Страница 6: ...e Home Screen Internet LAN connectivity BACnet with activation Control When the boiler is first energized the controller will go through a power up sequence that will take approximately 90 seconds Dur...

Страница 7: ...play will be showing the Home screen that includes details of the current boiler status If the controller has been left on the Home screen long enough user adjustable 10 minutes by default the display...

Страница 8: ...USER S INFORMATION MANUAL 8 SL SERIES BOILERS LIGHTING AND SHUTTING DOWN THE BOILER clockwise open close...

Страница 9: ...r and vacuum if required Check for water gas and condensate leaks in the boiler and around the boiler Check the condensate trap and clean if required Re fill the trap and re install the trap hook Chec...

Страница 10: ...chemicals or glycol solutions If the system employs plain water the boiler auto fill valve must be turned on in order to recharge the lost fluid Blocked Vent Safety System The boiler is equipped with...

Страница 11: ...11 USER S INFORMATION MANUAL SL SERIES BOILERS SERVICE RECORD DATE LICENSED CONTRACTOR DESCRIPTION OF WORK DONE...

Страница 12: ...USER S INFORMATION MANUAL 12 SL SERIES BOILERS NOTES...

Страница 13: ...13 USER S INFORMATION MANUAL SL SERIES BOILERS NOTES...

Страница 14: ...E MUST NOT BE USED UNLESS AT LEAST ONE OF THE FOLLOWING CONDITIONS IS TRUE An external energy management system is installed that reduces the boiler water temperature as the heating load decreases Thi...

Страница 15: ...REVISION HISTORY R1 JULY 2014 Initial release R2 MAY 2015 Address update...

Страница 16: ...IBC Technologies Inc 8015 North Fraser Way Burnaby BC Canada V5J 5M8 Tel 604 877 0277 Fax 604 877 0295 www ibcboiler com 120 203 A R2 May 2015 IBC Technologies Inc 2015...

Отзывы: