Qscan User’s Guide Version 1.4
Page
Wiegand Output Format # 1 (for barcode data)
X015 a mmmm ssss sd bbbb
X016 bd iiii id ss bb ii
X017 x y z lpp rpp h i j k
a
active indicator
0=inactive
1=active
mmmm
barcode length
0-1500
0000=any
ssss
site code start
0000=no site
sd
site code digits
00=remaining
bbbb
id start
0000=no id
bd
id digits
00=remaining
iiii
issue code start
0000=no issue
id
issue code digits
00=remaining
ss
site code bits
00=none
bb
id code bits
00=none
ii
issue code bits
00=none
x,y,z
backwards indicators
0=off (msb)
1=on (lsb)
lpp
left parity bits
000=none
rpp
right parity bits
000=none
h,i,j
field numbers for xmit
1=site,2=id
3=issue,0=none
k
site override
0=no
1=yes
see comments on the following pages.
Wiegand Output Format # 2 (for barcode data)
X019 a mmmm ssss sd bbbb
X020 bd iiii id ss bb ii
X021 x y z lpp rpp h i j k
see Wiegand Output Format # 1 for parameter descriptions
PROGRAMMING
BARCODE -> WIEGAND OUT