background image

SVT-

3

100 ACCESS CONTROL CARD READER 

(SVT19

100)

User Manual

Please read this user manual prior to installing the system, and keep it well for future use.

Summary of Contents for 3100

Page 1: ...SVT 3100 ACCESS CONTROL CARD READER SVT19100 User Manual Please read this user manual prior to installing the system and keep it well for future use ...

Page 2: ...rd type ID IC card card Capacity maximum 1000 Sensing distance 2cm Sensing time 0 8s Technical Parameters Ambient temperature 20 60 Relative humidity 95 Standby Current 90mA Operating Voltage DC 14 5V Operating Current 120mA Case screw Antenna SVT 3100 ACCESS CONTROL CARD READER SPECIFICATIONS ...

Page 3: ...stall into the wall Screw hole Screws Screw anchors Screws Screws fix with rain cover Rain cover Wall hole 105 mm 96mm 50mm fix with button case INSTALLATION without the rain guard INSTALLATION with the rain guard ...

Page 4: ... to main board module P8 4 2 Connect to main board module J1 Connect to main board module P3 4 2 Unlock button Connect to access control keypad Lock Power supply DC 14 5V Red Black Note If it is used as stand alone system disregard the wiring in dashed box ...

Page 5: ...power again and press in 3 seconds until Bi is heard It means admin code is restored successfully as default setting Press and then enter XXXX 4 digits admin code and A Di sound indicates entering to the setting mode successfully Press to return to standby mode No operation in 20 seconds will return automatically The factory default code is 4567 Enter the setting mode Modify access control code Se...

Page 6: ...rm that the setting is successful Registered card will be rejected After four Di sounds swipe master card again to return to standby mode Add user card In the setting mode Press 2 with a Di sound It is in the delete card mode Enter the last 6 digits of the card to be deleted If a Di sound is heard it indicates the deletion is successful Or swipe the card to be deleted if a Di sound is heard and an...

Page 7: ...e No operation in 30 seconds willreturn automatically Set building number and machine number In the setting mode Press 4 a Di sound is heard then enter 2 digits number from 01 to 99 as unlocking time If a Di sound and another DI sound are heard it indicates the unlocking time setting is successful Press to return to standby mode No operation in 30 seconds will return automatically Set the unlockin...

Page 8: ...The design and specifications of this user manual can be changed without any notification to the user All copyright and interpretation rights are reserved to SVT Innovations Inc ...

Reviews: