Troubleshooting
Your water conditioning system is designed and manufactured for efficient, low maintenance service.
However,
if problems do occur, this section provides a list of possible causes and solutions.
Alarms
The control continuously monitors itself and sends an error to the display if it detects something wrong. When
the error is sensed, the display shows the letters Err with a number from 1 to 4. Refer to microprocessor
troubleshooting procedures.
Refer to table 3 to help identify the cause of a problem. You can solve some problems yourself, such as low
salt in the storage tank or a blown household fuse. However, some problems require installer or dealer
assistance.
Table 3 – Troubleshooting Procedures
Caution
Service procedures that require the water pressure to be removed from the system are marked with
a ! after the possible cause. To remove water pressure from the system, put the bypass valve into
the shut off position and open the service line valve. Restore system water pressure when the
service work is completed.
Problem
Cause
Solution
1. Hard water at the tap.
a. Low or no salt in the salt storage
tank.
b. Capacity setting to low to
accommodate water hardness or
water usage.
c. Unit did not regenerate.
d. Plugged injector.
!
e. Air check valve prematurely closed,
in brine riser pipe.
a. Refill the salt storage tank and manually
initiate a regeneration. Refer to the
Manual Regeneration
section in this
manual.
b.
Reduce the capacity setting. Refer to the
Capacity Setting
section in this manual.
c. Check power.
d. Clean injector and screen. Refer to the
Cleaning the Injector/Injector Screen
in this manual.
e. Replace brine riser pipe if needed.
Check brine line connection for air
tightness.
2. Hard water leakage
during service.
a. Improper Regeneration.
b. Internal seal problem.
c. O-ring around riser tube damaged.
!
a. Check that the correct salt dosage is
used. Repeat regeneration.
b. Contact dealer.
c. Contact dealer.
3. Loss of power to the
system.
a. Transformer unplugged.
b. Fuse blown, circuit breaker open, or
circuit switched off.
a. Connect the power.
b. Correct the electrical problem.
4. Control does not
regenerate
automatically.
a. Transformer unplugged.
b. Defective control.
a. Plug transformer into outlet; plug trans-
former cable into control.
b. Contact dealer.
Содержание AS14100MP-CL
Страница 3: ...AS14100MP CL Page 3...
Страница 10: ...AS14100MP CL Page 10 MODEL AS14100MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI...
Страница 18: ...AS14100MP CL Page 18...
Страница 19: ...AS14100MP CL Page 19 WS1EI Screen Display Information And Programming Instructions...
Страница 21: ...AS14100MP CL Page 21 General Regeneration Error Screens Status...
Страница 28: ...AS14100MP CL Page 28 SPARE PARTS AND SERVICING INSTRUCTIONS...
Страница 37: ...AS14100MP CL Page 37 10 V3156 O ring 214 2 Flow Diagrams Service and Backwash flow diagram service...
Страница 38: ...AS14100MP CL Page 38 flow diagram backwash Flow Diagram Downflow...
Страница 39: ...AS14100MP CL Page 39 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Страница 40: ...AS14100MP CL Page 40 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Страница 48: ...AS14100MP CL Page 48 INJECTOR PERFORMANCE CURVES...
Страница 49: ...AS14100MP CL Page 49...
Страница 51: ...AS14100MP CL Page 51...