ibaRackline-PC CAM/HD
Manual
Issue 1.1
25
8.4.1
Power supply slide-in module for replacement of redundant power
supply unit
If the green lamp of a switched-on power supply unit does not light up during operation,
the appropriate power supply slide-in module must be replaced.
1 Fastening screw
1.
Loosen the fastening screw which is used to secure the power supply slide-in module
at the frame.
2.
Pull out the power supply slide-in module.
Replace the power supply slide-in module with the module of the same type (availa-
ble at iba).
8.4.2
Replacing the complete redundant power supply unit
1.
First remove the power supply slide-in module, as described above.
2.
Loosen the 4 fastening screws on the backside, which are used to fix the power
supply unit at the housing.