ibaRackline-PC CAM/HD
Manual
Issue 1.1
15
5.5
Default installation position for cards
On delivery, the data acquisition cards and additional cards are installed by default in the
slots described below.
Backview ibaRackline-PC CAM/HD
Specfic slots for the mainboards
Slot X2: controller
Installation slots for data acquisition cards (X3 - X7)
The cards are installed starting with slot X7 to slot X3
(X7 corresponds to the first card, card no. 0)
Installation slots for cards with rackline slots (X20 - X26)
ibaOut-Temp or ibaOut-State is installed in slot X20
ibaFOB-4o-D rackline-slot is installed starting with X25 and connected to X7 down-
wards.
ibaFOB-4o-D rackline-slot as sync-out (mirroring output ) is installed in X26 and
connected to X7
Connections of ibaFOB-4o-D with ibaFOB-D input cards:
X25 - X7
X24 - X6
X23 - X5
X22 - X4
X21 - X3
Installation slots for additional network cards
Additional network cards are installed starting with slot X3
GigE cards are installed in the slots X4 and X6
A PCI card is installed in slot X8 (e.g. CP1616)